Procedure 5-46: Clear
″
Pluggable Transmission Module
removed
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
Pluggable Transmission Module
removed
alarm indicated by a
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate, a continuously lighted port LED on the failed socket, and a
flashing
FAULT
LED on the circuit pack. The alarm is reported as
critical or minor in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
Pluggable Transmission
Module removed
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
Pluggable Transmission Module removed
alarm in
the resulting alarm list.
............................................................................................................................................................
2
Determine the alarm level for the
Pluggable Transmission Module
removed
alarm (for example, CR or MN). Clear the alarms in order of
severity, CR (SA) and then MN (NSA).
Important! The
Pluggable Transmission Module removed
alarm is generally either CR (SA) when the pluggable
transmission module is unprotected or MN (NSA) when the
pluggable transmission module is protected.
............................................................................................................................................................
3
Refer to the Probable Cause column in the alarm list, determine the
pluggable transmission module removed, and note the corresponding
socket AID.
............................................................................................................................................................
4
Using office records, determine if the required socket should contain a
pluggable transmission module.
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 3 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005