General Description of Operation
7
The DS1PM circuit pack terminates four bidirectional DS1 lines complying with
standard DSX-1 signal specifications. The DS1PM circuit pack interfaces to the
MXRVO/STS1E circuit pack at the VT-G rate (6.912 MHz) and to the SYSCTL.
The DS1 and DS1PM circuit packs are, with respect to transmission, functionally
equivalent. In addition to performing all of the functions of the DS1 circuit pack,
the DS1PM circuit pack provides PM for the DS1 rate transmit signals.
Detailed Description of Operation
7
Transmission Circuitry
7
Transmit Direction.
7
Figure 7-13 provides an overall block diagram of the DS1PM
circuit pack. The transmit direction points towards the VT-G and the receive
direction points toward the DS1s. In the transmit direction, the DS1PM receives
four balanced DS1 bipolar signals. Each of these signals passes through a relay
to a DS1 interface circuit that converts it to unipolar NRZ format, recovers its
clock, and sends it to the MUX and framing (framer) circuits. The MUX circuit
converts each DS1 rate input into a 1.728 Mb/s VT1.5 signal and then byte-
interleaves the four VT1.5s to create a VT-G signal that it sends to the MXRVO/
STS1E circuit pack, using the frame sync and clock received from the MXRVO/
STS1E.
Receive Direction.
7
The DS1PM receives a VT-G with clock and frame information
from the MXRVO/STS1E and demultiplexes the VT-G into four unique VT1.5
signals. Each VT1.5 passes through circuitry that performs pointer interpretation,
removes the VT path overhead bits, the fixed stuff bits, and the overhead
communications channel bits, and desynchronizes the embedded DS1. The DS1
rate signal is AMI or B8ZS encoded, pre-equalized with a selectable LBO, and
then sent as a balanced signal to a DSX-1 that may be located up to 655 feet from
the DDM-2000 OC-3.
Control Circuitry
7
The DS1PM circuit pack interfaces with the SYSCTL over the intra-shelf control
bus. Redundancy in the intra-shelf control bus assures the level of control
required to perform protection switching and alarming of a faulty circuit pack. The
DS1PM provides maintenance elements for reporting the status of the circuit pack
and the incoming VT1.5 and DS1 signals, as well as the circuit pack inventory
information (
CLEI
code, date of manufacture, etc.). These maintenance elements
are used by the SYSCTL for fault detection and isolation. Conversely, the DS1PM
responds to control signals from the SYSCTL (such as FAULT LED control). The
PM processor collects information from the framing circuitry and generates DS1
PM parameters which are sent to the SYSCTL.
Summary of Contents for DDM-2000 OC-3
Page 4: ......
Page 14: ...xiv Issue 3 June 2001 Contents GL Glossary GL 1 ...
Page 24: ...xxiv Issue 3 June 2001 Figures ...
Page 28: ...Tables xxviii Issue 3 June 2001 A A SONET Overview A 34 SONET Transport Rates A 20 ...
Page 58: ...363 206 285 About This Document lviii Issue 3 June 2001 ...
Page 60: ...1 ii Issue 3 June 2001 Table of Contents ...
Page 80: ...363 206 285 System Introduction 1 20 Issue 3 June 2001 ...
Page 154: ...3 ii Issue 3 June 2001 Table of Contents ...
Page 184: ...4 ii Issue 3 June 2001 Table of Contents ...
Page 252: ...363 206 285 Transmission and Synchronization Interfaces 5 60 Issue 3 June 2001 ...
Page 254: ...6 ii Issue 3 June 2001 Table of Contents ...
Page 278: ...7 vi Issue 3 June 2001 Table of Contents ...
Page 436: ...363 206 285 Circuit Pack Descriptions 7 158 Issue 3 June 2001 ...
Page 440: ...8 iv Issue 3 June 2001 Table of Contents ...
Page 518: ...363 206 285 Administration and Provisioning 8 78 Issue 3 June 2001 ...
Page 588: ...10 iv Issue 3 June 2001 Table of Contents ...
Page 690: ...363 206 285 Commands and Reports 11 20 Issue 2 February 2000 ...
Page 1252: ...11 582 2000 February 2 Issue OC 3 DDM 2000 ...
Page 1254: ...A ii Issue 3 June 2001 Table of Contents ...
Page 1276: ...363 206 285 A SONET Overview A 22 Issue 3 June 2001 ...
Page 1316: ......
Page 1348: ...363 206 285 Acceptance IXL 001 Issue 3 June 2001 Page 2 of 2 DDM 2000 OC 3 MULTIPLEXER ...
Page 1412: ...NTP 003 System Turnup 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1420: ...363 206 285 System Turnup NTP 004 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1440: ...NTP 008 Circuit Order 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1458: ...363 206 285 Circuit Order NTP 011 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1462: ...NTP 012 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1464: ...NTP 013 Circuit Order 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1508: ...363 206 285 System Turnup NTP 020 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1512: ...NTP 021 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1528: ...363 206 285 Circuit Order NTP 023 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1560: ...363 206 285 Circuit Order NTP 025 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1574: ...363 206 285 Circuit Order NTP 027 Issue 2 February 2000 Page 4 of 4 DDM 2000 OC 3 MULTIPLEXER ...
Page 1610: ...363 206 285 Circuit Order NTP 030 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1616: ...363 206 285 Circuit Order NTP 031 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1622: ...363 206 285 Circuit Order NTP 032 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1634: ...363 206 285 System Turnup NTP 034 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1652: ...363 206 285 Circuit Order NTP 038 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1702: ...363 206 285 System Turnup NTP 041 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1744: ...NTP 045 System Turnup 363 206 285 Page 8 of 8 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1808: ...363 206 285 Circuit Order NTP 052 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1866: ...363 206 285 System Turnup NTP 057 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1884: ...363 206 285 System Turnup NTP 059 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1912: ...NTP 002 Operation 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 2530: ...363 206 285 Page 2 of 2 Issue 3 June 2001 DDM 2000 OC 3 MULTIPLEXER ...