Example: If a fan is connected to a circuit that can be isolated via an
all-pole safety switch at the switchboard, then this is considered to be
an all-pole disconnection to the ceiling fan electrical circuit, meeting
the requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch on the active of the receiver input of remote
control must also be included in the wiring, and located the same
room as the ceiling fan.
5.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems available. If
electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
ground water and get into the food chain, damaging your health and well-being.
6. The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg.
7. The fan should be mounted so that the blades are at least 2.3m above the floor in Europe or 2.1m
above the floor in Australia.
8. This fan is suitable for indoor and alfresco areas where the fan is fully undercover with a minimum of
2 walls. This fan is not waterproof. When installed in an alfresco area, the ceiling fan must be
positioned in a location protected from water, wind, dust and salt. Exposure to these elements will
void the warranty. Mounting the fan in a situation where it is subject to water or moisture is
dangerous.
9. Only a licensed electrician should execute the installation.