LUCCI Airfusion Airmover Installation Instructions Manual Download Page 3

Airfusion Airmover Installation Instructions 

 

 

 

3 | 

P a g e  

 

       

 

 

 

Example: If a fan is connected to a circuit that can be isolated via an 

all-pole safety switch at the switchboard, then this is considered to be 

an all-pole disconnection to the ceiling fan electrical circuit, meeting 

the requirements of clause 7.12.2 of AS/NZS 60335.1.   

A single-pole switch on the active of the receiver input of remote 

control must also be included in the wiring, and located the same 

room as the ceiling fan.

 

 

5. 

  Do not dispose of  electrical appliances as unsorted municipal waste, use separate collection 

facilities. Contact your local government for information regarding the collection systems available. If 

electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the 

ground water and get into the food chain, damaging your health and well-being. 

6.  The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg. 

7.  The fan should be mounted so that the blades are at least 2.3m above the floor in Europe or 2.1m 

above the floor in Australia.   

8.  This fan is suitable for indoor and alfresco areas where the fan is fully undercover with a minimum of 

2  walls.  This  fan  is  not  waterproof.  When  installed  in  an  alfresco  area,  the  ceiling  fan  must  be 

positioned in a location protected from water, wind, dust and salt. Exposure to these elements will 

void  the  warranty.  Mounting  the  fan  in  a  situation  where  it  is  subject  to  water  or  moisture  is 

dangerous. 

9.  Only a licensed electrician should execute the installation. 

 

 

Summary of Contents for Airfusion Airmover

Page 1: ...V1 0 EN Published on 08 2017 LUCCI AIRFUSION AIRMOVER CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION...

Page 2: ...tended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning...

Page 3: ...le If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water and get into the food chain damaging your health and well being 6 The structure to...

Page 4: ...s Please refer to Fig 1 1 Mounting bracket x 1 8 Bottom cover x 1 2 Canopy x 1 9 Blade x 5 3 Down rod with ball joint x 1 10 Wooden screw x 2 4 Coupling cover x 1 11 Extra Motor screw x 1 5 Bolt x 1 1...

Page 5: ...g bracket to the ceiling joist or structure that is capable of carrying a load of at least 30kg with the two long screws provided Ensure at least 30mm of the screw is threaded into the support NOTE Th...

Page 6: ...pin back to the down rod 3 Insert the down rod to the coupling 8 line up the coupling holes with the down rod holes and insert the bolt 10 Then insert the pin 11 to the end of the bolt 4 Finally secu...

Page 7: ...ame process for the remaining four blades ELECTRICAL WIRING DIAGRAM WARNING FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED ELECTRICIAN NOTE AN ADDITIONAL ALL POLE DISCONNE...

Page 8: ...Airfusion Airmover Installation Instructions 8 P a g e USE WITH REMOTE WIRING DIAGRAM REMOTE sold separately 1 Remote without plugs 2 Remote with plugs Fig 8 Fig 9...

Page 9: ...on the power and check the operation of the fan OFF Position Fan off 3rd Position Low fan speed 2nd Position Medium fan speed 1st Position High fan speed Light Control Toggle Switch On off REVERSE FUN...

Page 10: ...ally at night you may hear occasional small noises Slight power fluctuations and frequency signals superimposed in the electricity for off peak hot water control may cause a change in fan motor noise...

Page 11: ...Airfusion Airmover Installation Instructions 11 P a g e FAN models Rated Voltage Rated power motor Rated power for light 56 FANS 220 240VAC 85W N A TECHNICAL INFORMATION...

Page 12: ...as a result of normal wear and tear 3 The product was installed by a licensed electrical contractor 4 A copy of the original receipt of purchase is presented 5 12 month warranty applies when used in...

Page 13: ...N LUCCI WARRANTY HOTLINE 1800 602 243 Complete and retain this form for your personal records and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER PO DATECODE Sticker here PO NUMBER or DATECODE DA...