47
46
DC Current
AC Current
Resistance
Open Circuit Voltage : < 1.3 V dc
Range
40 Hz – 400 Hz
Accuracy
400 µA
0.1 µA
4000 µA
1 µA
1.0 % + 5
40 mA
10 µA
400 mA
100 µA
4 A
1 mA
1.5 % + 10
10 A
10 mA
Resolution
Range
Accuracy
400 µA
4000 µA
1.0% + 2
40 mA
400 mA
4 A
10 A
0.1 µA
1 µA
10 µA
100 µA
1 mA
10 mA
1.5 % + 5
Resolution
Range
Accuracy
400
Ω
0.1
Ω
1.0 % + 5
1.5 % + 10
1.0 % + 5
4 k
Ω
1
Ω
0.5 % + 3
40 k
Ω
10
Ω
400 k
Ω
100
Ω
4 M
Ω
1 k
Ω
40 M
Ω
10 k
Ω
Resolution
Continuity
Diode Test
Capacitance
*
1
. Accuracy with film capacitor or better
Using
Mode
Frequency and Duty Cycle
Remark
Accuracy
Minimum frequency :
0.5 Hz
Sensitivity :
5 Hz–1 MHz, > 250 mV
1MHz–10MHz, >350 mV
0.001 Hz
0.01 Hz
0.05 % + 3
0.1 Hz
1 Hz
10 Hz
Range
5 Hz
50 Hz
500 Hz
5 kHz
50 kHz
500 kHz
100 Hz
5 MHz
1 kHz
10 MHz
10 kHz
0.1%
0.5 Hz to 500 kHz (pulse width > 2 µsec.)
(0.1% + 0.05% per kHz + 1 count) for 5 V input (Logic signals only)
0.1% to
99.9%
Resolution
Range
Accuracy
Open Circuit Voltage
4V
2%
Test Current
(Typical)
0.25 mA
< 1.5 V dc
Audible threshold
: the beeper sounds if the measured resistance is lower than
10
Ω
, and turns off when greater than about 60
Ω
.
Response time
: < 1 msec.
Range
Accuracy
2.5 % + 10
40 nF
10 pF
400 nF
100 pF
4 µF
1 nF
40 µF
10 nF
100 µF
100 nF
Resolution
*
1
*
1