background image

 

 

Intelligent LED Driver

(Constant Current)

0 . 0 1 - 1 0 0 %

SE-12-100-400-W1Y

Tuya Bluetooth Mesh

Output voltage

:

9-42Vdc

Frequency

:

0/50/60Hz

Max output voltage

:

50Vdc

Input current

:

115Vac≤0.2A, 230Vac≤0.1A 

Output current

:

100-400mA

Power factor

:

PF≥0.95/115Vac , PF≥0.85/230Vac

 

(Full load)

Tuya Bluetooth Mesh

Wireless type

:

Input voltage

:

100-240Vac (120-300Vdc)

 

Anti surge

:

L-N: 1kV

Dimming range

:    

0~100%, 0.01% depth dimming

Working temperature

:

 ta: -20

 

~

 

50°C

   

tc: 75°C  

    

 

Current accuracy

:

±5%

Working humidity

:

20

 

~

 

95%RH,

 

non-condensing

Ripple & noise

:

≤2V

Leakage current

:

<0.24mA/230Vac

LF current ripple (<

120Hz)

:

<1%

Vibration

:

10~500Hz, 2G 12min/1cycle, 72 min for X

Y and Z axes respectively

≤3600Hz

PWM dimming frequency

:

Efficiency (Typ)

:

80% 

1W~12W

Load power range

:

Inrush current

:

Cold start5A@230Vac (Test twidth=40 us tested under
50% lpeak)

Flicker level

:

No visible flicker/High frequency
exemption level

Technical Specs

Adopt SAMSUNG/COVESTRO

 

V0 flame resistant polycarbonate protective

housings with small size and light weight. 

Bluetooth Mesh & Tuya application protocol with high networking
capability are reliable and stable. 

Support control iOS or Android devices through Bluetooth connection

T

-

PWM

dimming technology allows continuous and flicker-free

images under high-speed shooting. 

0-100% flicker-free dimming with high frequency exemption level.

Dimming from 0~100%, down

 

to

 

0.01%.

Innovative thermal management technology protects the power
life intelligently. 

Overheat, over voltage , overload, short circuit protection and
automatic recovery.

Suitable for indoor light applications of

Ⅰ/Ⅱ/Ⅲ

type

.

Up to 50,000-hour life time. 

5-year warranty (Rubycon capacitor).  

Super depth dimming technology

Flicker-free

IEEE 1789

Flicker-free

IEEE 1789

Overload

protection

Overheat

protection

Short circuit

protection

Super depth

dimming technology

Protection

Safety & EMC

Overvoltage protection

:

Shut down the output and recover automatically
once it exceeds no-load voltage. 

Overload protection

:

Shut down the output and recover automatically
once it exceeds 1.02 times of the max load power. 

Overheat protection

:

Intelligently adjust or turn off the output current if the
PCB temperature ≥110°C, and recover automatically

Short circuit protection

:

When short circuit occurs, shut down the output and
recover automatically. 

I/P-O/P:3750Vac

Withstand voltage

:

I/P-O/P:500Vdc/1min/25°C/70%RH≥10MΩ

Insulation resistance

:

IEC/EN61347-1, IEC/EN61347-2-13

Safety standards

:

EN55015, EN61000-3-2 , IEC61000-3-3

EMC emission

:

EN61000-4-2,3,4,5,6,8,11,  EN61547

EMC immunity

:

IEEE 1789

Strobe test standard

:

Others

Dimensions(LxWxH)

:

 167x41x32mm

Package size(LxWxH)

:

 168x43x35mm

Gross weight 

:

 120g±10g

— 01 —

www.ltech-led.com

|

Strategic Partnership 

With soft-on and fade-in dimming function enhancing visual comfort. 

Summary of Contents for T-PWM SE-12-100-400-W1Y

Page 1: ...free dimming with high frequency exemption level Dimming from 0 100 down to 0 01 Innovative thermal management technology protects the power life intelligently Overheat over voltage overload short circuit protection and automatic recovery Suitable for indoor light applications ofⅠ Ⅱ Ⅲ type Up to 50 000 hour life time 5 year warranty Rubycon capacitor Super depth dimming technology Flicker free IEE...

Page 2: ...ection DIP switch quickly selects multiple current value See the table below Please set current value when the driver is power off Output current Output voltage Output power Product Size DIP switch Wiring Diagram 1 ON 2 3 N L DIM 0 100 0 5 2 5 0 75 2 5 Wire diameter 0 75 2 5 Strip length 5mm 6mm Wire diameter 0 5 2 5 Strip length 5mm 6mm Access the network to control through App and Bluetooth 02 w...

Page 3: ... Table IEEE 1789 f f 8Hz 10Hz Limit value Exemption assessment High frequency exemption f f f f f f f f f f 90Hz 90Hz 1250Hz 3125Hz 8Hz 10Hz 90Hz 90Hz 1250Hz 3125Hz 0 2 0 1 0 025 0 01 0 08 0 08 2 5 Limit Value of Modulation in Low Risk Areas Waveform frequency of Optical output Exemption assessment Limit Value of Modulation in No Effect Areas Waveform frequency of Optical output Limit value Modula...

Page 4: ...cation then add the rooms you need Click Add Device Auto Scan and enable permissions for automatically scanning Bluetooth Wi Fi Zigbee wired devices Follow the prompts to add the device Ensure that the device is ready for network connection 3 Lighting control settings After paring up your device click the device you add and adjust to your desired lighting status by changing brightness In Settings ...

Page 5: ... the lighting remotely by clicking Automation in the Smart menu In Automation set up conditions from weather location and timing to other device status so as to trigger the lighting effects you preset and realize the lighting automation Reset The Device Reset to factory defaults When the driver is power on turn it off and after 15s turn it on After 2s turn it off again Repeat the same operation 5 ...

Page 6: ... is subject to changes without further notice Product functions depend on the goods Please feel free to contact our official distributors if you have any question Products shall be installed by qualified professionals LTECH products are non waterproof special models excepted Please avoid the sun and rain When installed outdoors please ensure it is mounted in a water proof enclosure Good heat dissi...

Reviews: