background image

LED INDICATOR STATUS MESSAGES

 

 

The LED indicator communicates to the final user the status of the 

FI750/RF/PA

.

 

POWERING UP AND LINKING 

-

 PRELIMINARY NOTES

 

 

FI750/RF/PA

 needs to be powered up with the supplied batteries.

 

 

Linking is the operation through which 

FI750/RF/PA

 is 

wirelessly connected

” 

to a 

FI750/RF/W2W

FI750/RF/CWE

 or 

FI750/RF/WE

 compati-

ble network device.

 

 

POWERING UP 

-

 FIRST TIME USE

 

 

Use this procedure the first time you power up a 

FI750/RF/PA

.

 

 

1)

 

Make sure the Link / program switch is set on 

ON

”.

 

 

2)

 

Insert the two supplied batteries into their device

s lodgments.

 

 

Ensure that the batteries are installed properly, with their polarities matching the indications on the device.

 

 

POWERING UP 

-

 DEVICE LINKED TO THE SYSTEM

 

 

Use this procedure when a 

FI750/RF/PA

 is successfully linked to its compatible system and you have to extract one or both batteries (e.g. 

batteries substitution).

 

 

1)

 

Reinsert the battery or both batteries into their lodgments.

 

 

Do not touch the Link / program switch.

 

If performing a batteries substitution, use two brand new batteries and substitute both of them.

 

Ensure that the batteries are installed properly, with their polarities matching the indications on the device.

 

 

POWERING UP 

-

 RECOVERY

 

 

Use this procedure when you fail to link successfully a 

FI750/RF/PA

 or you want to link it again.

 

 

1)

 

Move alternatively the Link / program switch 5 times.

 

 

2)

 

Set the Link / program switch on 

ON

”.

 

 

3)

 

Insert the two supplied batteries into their device

s lodgments.

 

 

Ensure that the batteries are installed properly, with their polarities matching the indications on the device.

 

 

LINKING 

-

 WAKE

-

UP

 

 

Wake

-

up

” 

linking consists in associating one or more child devices to the compatible system altogether in a single operation.

 

Wake

-

up is performed either through the 

TauREX

 software or the 

FI750/RF/W2W

 / 

FI750/RF/CWE

 keyboard

-

screen interface; it CANNOT be 

done through 

FI750/RF/WE

 devices.

 

 

1)

 

Create the 

virtual model

” 

(be aware that the 

Output Module 

type has to be selected to link a remote indicator) of the 

FI750/RF/PA

 either 

on 

TauREX

 or on the 

FI750/RF/W2W

 / 

FI750/RF/CWE

 

 

2)

 

Power

-

up the remote indicator (either 

first time use

” 

or 

recovery

”).

 

 

3)

 

Set the Link / program switch OPPOSITE to 

ON

”.

 

 

4)

 

Trigger the wake

-

up procedure either from 

TauREX

 or from the 

FI750/RF/W2W

 / 

FI750/RF/CWE

.

 

 

5)

 

Wait the end of the 

wake

-

up

” 

linking procedure.

 

 

6)

 

Check on 

TauREX

 or from 

FI750/RF/W2W

 / 

FI750/RF/CWE

 for linking success. Consult their user manual.

 

 

L20

-

TWRI1

-

30EN (vP.1)

 

 

2

 

Table 1

 

Please  mind  that  LED  signalling  burns  out 

battery  power,  therefore  reducing  batteries 

lifespan.

 

Device status

 

LEDs indication

 

Power up (DIP on 

ON

”)

 

Blinks red 4 times

 

Power up (DIP opposite 

ON

”) 

 

Blinks green 4 times 

 

Entering wake

-

up mode

 

Blinks alternatively green / red 4 times

 

Link success (one

-

by

-

one)

 

Blinks green 4 times, then the same pattern again

 

Link failure (one

-

by

-

one)

 

Enters wake

-

up mode and signals 

Entering wake

-

up mode

” 

following this failure

 

Link success (wake

-

up)

 

Blinks green 4 times, then same pattern again

 

Link failure (wake

-

up)

 

Blinks green 4 times, then blinks red on once, then blinks alternatively green / red 4 times

 

Normal condition

 

LED off (can be programmed so as to blink green every wireless communication)

 

Alarm activation

 

Red LED steady on

 

Battery fault

 

LED off (can be programmed so as to blink amber every 5 seconds)

 

Tamper fault

 

LED off (can be programmed so as to blink amber every 5 seconds)

 

Replaced

 

Blinks green 4 times

 

Summary of Contents for FI750/RF/PA

Page 1: ... as well as cable conductors cables especially from computers otherwise the operating distance may greatly drop The FI750 RF PA must NOT be installed near electronic devices and computer equipment that can interfere with its wireless communication quality FI750 RF PA Wireless Remote indicator Battery A housing Tamper switch Link program switch Battery B housing Picture 1 DEPLOYMENT PROCEDURE 1 Sel...

Page 2: ...UP Wake up linking consists in associating one or more child devices to the compatible system altogether in a single operation Wake up is performed either through the TauREX software or the FI750 RF W2W FI750 RF CWE keyboard screen interface it CANNOT be done through FI750 RF WE devices 1 Create the virtual model be aware that the Output Module type has to be selected to link a remote indicator of...

Page 3: ...e 3 1 Screw the grain inwards until it stops 2 Press the tab shown in the picture and gently and carefully remove the cover Reinstalling the cover consists in performing the operation portrayed in picture 3 TAMPER DETECTION FEATURE The opening of the wireless remote indicator s case is signaled by the control panel as a tampering attempt the device s PCB is equipped with a spring tactile switch as...

Page 4: ... is advisable to replace the devices in order to minimize the risk of reduced performance caused by external factors Ensure that this device is only used with compatible control panels Detection systems must be checked serviced and maintained on a regular basis to confirm correct operation Smoke sensors may respond differently to various kinds of smoke particles thus application advice should be s...

Reviews: