Aiming Laser or Tubing
Handle Bolt
Moun�ng Hardware
1. Insert the laser or tube into the aiming mount and �ghten the holding screw.
2. Insert the aiming mount onto the fixture aiming pin un�l it is fully seated. Aiming mount must be �ght against the
fixture because any movement or wiggle in the mount will cause aiming to be inaccurate.
3. Slightly loosen the fixture aiming screws just enough to allow the fixture to rotate and �lt.
4. Turn on the laser and aim the fixture by targe�ng the red laser dot at the aiming point. If aiming tube is used, look
through tube and adjust fixture un�l aiming point is centered in view through tube. Refer to photometrics or project
installa�on drawings for aiming point coordinates.
5. A�er aiming is complete, �ghten all bolts and screws including hex and set screws on side of fixture and moun�ng
hardware.
6. Briefly turn the laser back on or re-check view through tube to verify that the luminaire aim did not shi� during
�ghtening.
7. Remove the aiming mount from the fixture and proceed to the next luminaire.
Equipment Required:
● Laser or Aiming Tube
● Aiming Mount
● 15/16” (or metric equivalent) Socket Wrench
● 3/16” (or metric equivalent) Hex driver
● Torque wrench/driver
Tilt is a vector in the
y-plane from the hex
bolt that is parallel with
the top of the visor
Figure 7. Tilt
Figure 8. Aiming Laser & Mount
NEVER use any power tools on the fixture while the power is on. The vibra�on caused
by power tools may damage the fixture. FAILURE TO FOLLOW THIS WARNING MAY
LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE.
WARNING
Note:
For outdoor day�me aiming when the laser dot is difficult to see, a piece of rigid
tubing may be used in place of the laser. Outside diameter of tube must be
0.8”- 0.87” (ANSI NPS ½”; 20-22 mm) to fit into the Aiming Mount. Slightly smaller
conduit such as ½” (16 Metric) EMT (Electrical Metallic Tubing) may be used in the
mount with a grommet or other shim only if the shim is evenly distributed around
the tubing to keep it correctly aligned parallel with the top front visor of the luminaire.
NEVER point the aiming laser at any person or animal as it can cause permanent
damage to eyes. Use laser only for aiming fixtures as directed. FAILURE TO FOLLOW
THIS WARNING MAY LEAD TO SEVERE INJURY.
WARNING
Note:
Turn off laser while not in use to conserve ba�ery. Have spare ba�ery charged to
facilitate the aiming process.
Note:
A�er targe�ng the aiming point with the laser, turn off the laser to conserve ba�ery life.
9
10
270°
270°
180°
0°
90°
150mm(5.9ʺ)
Φ83.5mm(Φ3.3ʺ)
Φ21mm(Φ0.83ʺ)