background image

Step 3 – Make Electrical Connec�ons

Equipment Required:

●   Moun�ng Hardware
●   Socket wrenches and/or crescent wrenches sized to fit moun�ng hardware
●   Cable �es or wire management – For outdoor installa�ons use UV rated

Equipment Required:

●    3/16” driver (or metric equivalent)
●     Power cable
●      Electrical splicing connectors. For all outdoor installa�ons, silicone filled water resistant 
         connectors are highly recommended.

Notee:

 Example moun�ng structure shown for illustra�on purposes only.

Standard Moun�ng

This is the most common moun�ng. The luminaire sits on top of moun�ng structure.
1. Refer to the project Installa�on Drawings to determine luminaire installa�on loca�ons 

     and lens type.
2. For each fixture loca�on, install a luminaire that has the correct lens type. Unless 

     otherwise noted, fixtures that share the same lens type are iden�cal.
3. Set luminaire in place and install bolt, flat washers, and nut to securely fasten the fixture

      moun�ng bracket to the moun�ng structure.Tighten hardware hand �ght so that fixture 

      is secure but do not fully torque hardware un�l aiming is complete.

SLI Moun�ng

A�ach the light to the pole with slip fii�er mount (screw size 5/16

Hex bolt

Flat washers

Hex Locknut

Moun�ng hardware shall be high-strength, corrosion-resistant material. Length of Hex bolt 

shall be determined in the field; size the bolt appropriately to allow secure fastening of the 

luminaire to the moun�ng structure.

An impact driver may be used on moun�ng hardware while the power is off, but NEVER 

use any power tools on the fixture while the power is on. The vibra�on caused by power

tools may damage the fixture. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO 

LUMINAIRE INTERNAL DAMAGE AND FAILURE.

WARNING

Never connect the luminaire to an electrical system that is not grounded. Installing a 

luminaire in an ungrounded electrical system could allow the metal housing to become 

energized in the event of an electrical short, resul�ng in the risk of electrical shock for 

anyone who comes into contact with the fixture. FAILURE TO FOLLOW THIS WARNING

MAY LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.

WARNING

Moun�ng Hardware Required

Figure 3. Standard Moun�ng

Figure 4. SLI Moun�ng

Hardware Required

Hex bolt 

M20*120mm

Flat washers 

Φ21mm 

Flat washers 

Φ10.5mm 

Spring washers

Quan�ty per luminaire

1
1
1
1
2
2
2
2

Φ21mm

Spring washers

Φ10.5mm

Hex Locknut

M20

Hex Locknut

M10

Size 

Hex bolt 

M10*120mm

5

6