Chapter2. Profibus-DP Communication Module
5
2.4 Installation
Warning) Connect a communication network after the power supply
is off.
If Profibus-DP communication module is removed or
installed, the power supply should be switched off. Otherwise, the
S100 inverter will be damaged entirely.
Take off Profibus-DP communication module from the product after
the power supply is totally discharged.
■
Unfasten the front cover fixing bolt
to remove the front cover and
remove I/O cover((1), (2)) from
a dedicated inverter
for communication.
■
Remove the keypad (3).
■
Unfasten a screw from
I/O board and
fasten the prepared
brass bar(4).
(1)
(2)
(3)
(4)