■ Setting the operating time

ᆞ Set the time knob according to the characteristics

of the load.

ᆞ The operating time can be adjustable from 0sec to 

30sec.

!

CAUTION

ᆞ Installation, maintenance and inspection of the 

product should be performed by qualified engineers
having special knowledge. 

ᆞ Use the product in a range of the rated voltage

and current shown on the name plate.

It may cause malfunction.

ᆞ Connect control power at terminal A1,A2.
ᆞ Refer to wiring diagram for proper terminal 

connection.

ᆞ After wiring, Cover the Finger Proof necessarily.
ᆞ When the device useless, it should be dispose of 

them as an Industrial waste.

■ Installation

Operation & Setting Method

ᆞ Insert the finger proof necessarily in the terminal

block, after wiring.

ᆞ Do not turn the knob more then 2kg force, when

you set the time & current.

Summary of Contents for META MEC Series

Page 1: ...ead the instruction manual and safety precautions before use products This manual should be given to the person who actually uses the products and is responsible for their maintenance WARNING Offending against the message will result in death or serious injury CAUTION Incorrect handling of the device may result in minor injury or physical damage ...

Page 2: ...urn off the upstream breaker before installing or service to prevent electric shocks and burn due to short circuit It make an electric shock and burn to short circuit ᆞ Do not touch any live naked terminals It make an electric shock ᆞ Install the noise filter in the external if the harmonic is more than 30 It may cause malfunction Introduction The LG GMP series Electronic Motor Protection Relay pr...

Page 3: ...in a range of the rated voltage and current shown on the name plate It may cause malfunction ᆞ Connect control power at terminal A1 A2 ᆞ Refer to wiring diagram for proper terminal connection ᆞ After wiring Cover the Finger Proof necessarily ᆞ When the device useless it should be dispose of them as an Industrial waste Installation Operation Setting Method ᆞ Insert the finger proof necessarily in t...

Page 4: ...check the relay by pressing the button In motor running the key can t be operated for safety ᆞ When the EMPR is tripped Push the button and that is reset ᆞ Refer to device rating label for fault indication Setting the current ᆞ Start the Motor with the rated current knob RC at the Max ᆞ Turning around the RC knob to the counter clockwise check the point Led start flashing That point is the actual ...

Reviews: