Power Rating
The rated voltage of the module is max 48.6V. If the applied voltage is over 48.6V,
charging the module should be stopped. And the allowable low voltage level of the
module depends on the user’s requirements, but full discharging to 0V does not
affect the module performance.
Temperature
The module has its optimal operating temperature range of -40 to 65. Over 70
℃
,
charging and discharging should be stopped to expect its performance and life
cycle.
Do not expose to direct sunlight
For installation do not make the module expose to direct sunlight due to
temperature increase inside the module.
Maintenance
The module has its expected life cycle over 10years at rated voltage and +25
℃
.
However the life cycle of the module may be decreased in high temperature
condition or over voltage charging.
If following abnormal module performances are detected, operation should be
stopped and checking the electrical & mechanical connections is recommended.
- Monitoring high temperature in normal operating conditions
- Internal resistance increase or initial voltage drop increase
- Deformation of the module case