IV5 EnDat Option Manual
13
6. Functions
(1)
DIS_01~03(Display EnDat version)
The Parameter of
‘Sin/Cos EnDat’ displays the version of EnDat option board in
DIS_01~03.
Code
LCD
display
Description
Setting
range
Unit
Setting
DIS_01
~
DIS_03
User disp1
~
User disp3
User-defined
display
-
-
Sin/Cos EnDat
(2) PAR_10(Pulse count of encoder)
In the case pulse count
is “2048”, IV5 EnDat option board can be supported.
If you use the encoder of other pulse count, Please contact with the LS ELECTRIC website
FAQs.(http://www.lselectric.co.kr)
Code
LCD
display
Description
Setting
range
Unit
Factory setting
PAR_10
Enc Pulse
Pulse count of
encoder
2048
-
2048
(3) PAR_11(Encoder direction setting)
Set the direction of encoder.
Code
LCD
display
Description
Setting range
Unit
Factory setting
PAR_11
Enc Dir Set
Encoder direction
setting
A Phase Lead/
B Phase Lead
-
A Phase Lead