Learning Advanced Features
278
8.36
Traverse Operation
The traverse operation is used to periodically change the motor rotation. In its application as a
winder, the traverse operation ensures that the thread or wire is evenly wound on a spindle
without tangles.
Group Code
Name
LCD Display
Parameter Setting Setting Range Unit
APP
01
Applied function
selection
App Mode
1
Traverse
0
–
4
-
08
Traverse operating
range
Trv Amplit %
-
0.0
0
–
20
%
09
Traverse scramble
magnitude
Trv Scramb %
-
0.0
0
–
50
%
10
Traverse
acceleration time
Trv Acc Time
-
2.0
0.1
–
600.0
Sec
11
Traverse
deceleration time
Trv Dec Time
-
3.0
0.1
–
600.0
Sec
12
Traverse offset
upper limit
Trv Offset Hi
-
0.0
0
–
20.0
%
13
Traverse offset
lower limit
Trv Offset Lo
-
0.0
0
–
20.0
%
IN
65
–
75
Px terminal
configuration
Px Define
(Px: P1
–
P8
[optional:
P9
–
P11])
27
Trv Offset
Lo
-
-
28 Trv Offset Hi -
-
Traverse Operation Details
Code
Description
APP-01 APP Mode
Set APP-
01 to “1 (Traverse)”. Parameters for the traverse operation
become visible.
Setting Function mode
0
None
1
Traverse
2
Proc PID
3
Reserved
4
Auto Sequence
Summary of Contents for SV-iS7 Series