10. Object Dictionary
10-102
10.4
CiA402 Objects
0x603F
Error Code
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
-
0
-
RO
Yes
-
No
The last alarm code (HEX value) that occurred in the servo drive is displayed.
0x6040
Controlword
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 0xFFFF
0
-
RW
Yes
Always
No
This is composed of bits that control the drive state, the operation mode, and manufacturer-specific
options.
Bits
Function
Description
0
Switch on
Refer to the description below of bits 0 to 3.
1
Enable Voltage
2
Quick stop
3
Enable operation
4 to 6
Settings by
Operation Mode
Refer to the description below of bits 4 to 9.
7
Fault Reset
0
1: Alarm/warning reset
8
Halt
Refer to the description below of bits 4 to 9.
9
Settings by
Operation Mode
10
–
-
11 to 15
–
-