background image

i-MessageAlarm / ES 906

Alarm unit with remote configuration via Ethernet network and 

possibility for e-mail alarm.

Summary of Contents for i-MessageAlarm ES 906

Page 1: ...i MessageAlarm ES 906 Alarm unit with remote configuration via Ethernet network and possibility for e mail alarm ...

Page 2: ...cal Connections 4 Connecting the Patch Cable 5 Start up of the i MessageAlarm 5 Overview and Functions 6 Overview 6 E mail Setup 7 Function Setup 8 Temperature Setup 9 Network Password Setup 10 Factory Settings 11 Custom Setup 11 Technical Specifications 12 WEE 12 Applicable Standards 12 ...

Page 3: ... or sms with a text message of your choice in case of alarm To receive alarms via sms it requires configuration of email to sms converting from one of the many providers of this service on the internet Sim card is not required and is not a possibility It is not necessary to connect the i MessageAlarm to the internet for operation as a local alarm unit Internet connection is however required to cha...

Page 4: ...veillance switch Must be voltage free J5 Connector for connection cable front J9 Connection of temperature sensor NTC 10K or NTC 22K Ethernet Connection of network cable to existing network hub switch or router RJ45 network cable Master reset Press the reset button for 4 seconds on connection of 230V supply to reset the unit A short beep indicates that the unit has been reset The backup battery mu...

Page 5: ...e connected to the same network it is important to connect one alarm at a time and change give the alarm a name hostname before connection the next alarm Otherwise the internet is not able to identify the separate alarms from one another Please Note When establishing contact to already connected i MessageAlarms you need to enter the hostname into the internet browser i MessageAlarm must be connect...

Page 6: ...w of all factory settings in the i MessageAlarm Note some menus requires entry of username and password The default values are admin and 12345 respectively Overview Setting Function Functionality Shows whether the Voltage free contact set is set up to be Normally Open or Normally Closed Operating Status Shows if the alarm function is tuned on or off Alarm Shows if the alarm is in alarm mode at thi...

Page 7: ...rovider From Email Configuration Email address Address to be used to log on to the SMTP server SMTP Server IP address on SMTP server User Name User name for SMTP server typical email address user name Password Password for SMTP server typisk password for email address To Email Configuration To Address of the person to whom the mail is to be sent Subject Enter subject to be displayed on the alarm m...

Page 8: ...or repeating alarm text message per alarm incidence Max Email Repeat Set up the number of times alarm text message is to be sent per alarm incidence Sound Period The period from one beep starts till next beep starts Can be set to 1 10 of 1 255sec E g sound periode is set to 10 it takes 1sec from beep starts till next beep incl period of silence Sound Duty Cycle Lenght of beep in percent of sound p...

Page 9: ...rtant to press Save if changes have been made Setting Function Operation Choose ON OFF to activate deactivate temperature alarm NTC model Choose if connected temperature sensor is 10K or 22K NTC Temperature Shows current temperature if temperature sensor is connected Setup Setting of min and max temperature limits for temperature alarm Email message Alarm text message to be sent in case of tempera...

Page 10: ...een made Setting Function MAC Address Displays the unique address of the product If changed it may take a few minutes before contact to i MessageAlarm is re gained depending on network settings Host Name Can be changed to desired name on web server Must be changed in case of multiple i MessageAlarms on same network Avoid special characters and æ ø å Enable DHCP Use automatic IP address allocation ...

Page 11: ... Model 10K 10K 22K Setup Min 10 C 20 C 100 C Max 50 C 20 C 100 C Email Message Temperature Alarm For entering of user defined alarm text Network Password Setup MAC Address See browser Can be manually changed Default is restored by MasterReset Host Name i messagealarm Multiple alarms on same network must be named differently Enable DHCP ON OFF ON IP Address Blank Only to be used on networks without...

Page 12: ...trical and electronic equipment is marked with a crossed out weelie bin logo This logo symbolises that electrical and electronic equipment must not be disposed of together with normal household waste but must be collected separately Contact your local authorities for further information on disposal of equipment under the WEE directive Applicable Standards EN 61000 6 1 and EN 61000 6 2 Electromagne...