Long Range Systems
6
T9550 LCM User Manual
MAINTENANCE CHECKS
The performance of the T9550 may be checked and adjusted
Change System ID
This function is used where neighboring establishments use LRS equipment and may in-
terfere with each other. Pagers and Transmitter MUST be on the same ID.
1. Press 9 0 X (X = ID 0, 1, 2, or 3).
2. Press Prog
Change Station ID
This function is used where more than one transmitter is used in one establishment. This
allows the staff pager to vibrate 1, 2 or 3 times (for station 1, 2, or 3).
1. Press 9 9 X (X =1, 2, or 3).
2. Press Prog
Checking the Battery
If operating on battery power, disconnect the transmitter from the adapter and press Prog.
The unit will show a number from 0 to 5
• If the unit shows 4 or above the charge is adequate for normal use
• If the unit shows 3, it is ok for short term use (1 or 2 hours)
• If the unit shows 2 or less (including blank) it must be recharged before use.
Reset to Default Paging Mode.
For units that may have had the battery completely discharged.
1. Connect the charger.
2. Press the reset button on the side of the transmitter and charge for 24 hours.
3. Enter 0 0 0 and press Prog key
Range Test
Range test is used to determine if there are areas of your establishment where the pagers
are not reliably paged. Usually moving a fixed transmitter a few feet solves this problem.
Mobile transmitters may sometimes be blocked by metal kitchen equipment. To perform
a range test:
1. Remove a pager(s) from the charger.
2. Press 9 1 2 Prog. The transmitter will show a 0 in the display that moves right to
left. All pagers will receive this message.
3. Move the pager(s) and Transmitter to different locations to determine if any dead
spots exist