LRS CurbAlert Install Manual Download Page 23

Warranty

Long Range Systems, Inc. warrants this product against any defects that are due to faulty material or workmanship for
a two-year period after the original date of consumer purchase.  This warranty does not include damage to the product
resulting from accident, misuse or improper electrical connection. If this product should become defective within the war-
ranty period, we will repair or replace it with an equivalent product, free of charge. LRS will return your product via UPS
ground shipping. All warranty claims must be initiated through our customer service department.

Copyright © August 2009, Long Range Systems, Inc.  All Rights Reserved

This manual contains proprietary information of Long Range Systems, Inc. (LRS) and is intended for use only by its em-
ployees or customers.  None of the material contained herein may be copied, reproduced, republished, downloaded, dis-
played,  posted,  or  transmitted  in  any  form  or  by  any  means,  including  but  not  limited  to,  electronic,  mechanical,
photocopying, recording, or otherwise without the prior written permission of LRS.  Additional copies of this manual may
be obtained by contacting LRS.

Screen displays, keyboard layouts, hardware descriptions, or software are proprietary to LRS and are subject to copy-
right and other intellectual property rights of LRS and shall be treated in accordance with the previous paragraph.

All attempts have been made to make the information in this document complete and accurate.  LRS is not responsible
for any direct or indirect damages or loss of business resulting from inaccuracies or omissions.  Specifications and other
information contained within this document are subject to change without notice.

Long Range Systems, Inc. reserves the right to make changes without further notice to any products herein. LRS, Inc.
makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor
does LRS, Inc. assume any liability arising out of the application or use of any product or circuit, and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. “Typical” parameters that may be
provided in LRS, Inc. data sheets and/or specifications can and do vary in different applications and actual performance
may vary over time. All operating parameters, including “Typicals”, must be validated for each customer application by
customer’s technical experts. LRS, Inc. products are not designed, intended, or authorized for use as components in sys-
tems intended to support or sustain life, or for any other application in which the failure of the LRS, Inc. product could
create a situation where personal injury or death may occur. Should Buyer purchase or use LRS, Inc. products for any
such unintended or unauthorized application, Buyer shall indemnify and hold LRS, Inc. and its officers, employees, sub-
sidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney
fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unau-
thorized use, even if such claim alleges that LRS, Inc. was negligent regarding the design or manufacture of the part, de-
vice or system.

EU DECLARATION OF CONFORMITY

We, Long Range Systems hereby declare under our sole responsibility that the CurbAlert paging on-site pagers comply
with the essential requirements in the European RE&TTE Directive 1999/5/EC of the European Parliament of the Council
of 9 March 1999 on radio equipment and telecommunication terminal equipment and the mutual recognition of their con-
formity.  The following standards were utilized:

ETS 300 224: 1998

EN 301 489-2: 2002

EN61000-3-2: 1998

EN 61000-3-3: 1995

EN 60950: 1992 with A1, A2, & A3

Long Range Systems

22

CurbAlert User Manual

XU-0044 110209

Long Range Systems UK Ltd | Link House | Leek Road | Milton | Stoke on Trent | Staffordshire | ST2 7AH | 01782 537000
www.lrspagers.co.uk | www.pagers.co | www.hospitalpagers.co.uk

Summary of Contents for CurbAlert

Page 1: ...d S Se er rv vi ic ce e I In nf fo or rm ma at ti io on n CurbAlert Paging System Transmitter INSTALL MANUAL Long Range Systems UK Ltd Link House Leek Road Milton Stoke on Trent Staffordshire ST2 7AH 01782 537000 www lrspagers co uk www pagers co www hospitalpagers co uk ...

Page 2: ... Network Setup 8 Network Signal Connections Alternate Connection 11 Configure System 12 General Procedure 12 Setup System Screen 13 Network 13 Camera 13 Software Upgrade 13 Setup Paging Screen 14 Pagers 14 Setup Schedule Screen 15 Manager Paging 15 Duty Paging 15 Zones Screen 16 Alert Zone Setup 16 Greet Zone Setup 17 Tuning Screen 18 Location Setting Screen 19 OEM TX Setup 20 Service Questions an...

Page 3: ... or XP and LRS camera adjustment software Crossover cable connected to camera CAT 5 cable on a reel enough to do a 100 ft installation CAT 5 crimping tool 18 2 speaker wire enough to do a 100 ft installation Surge Protector in case an extra is needed Phillips Head Screwdriver Wire Cutters Strippers RJ 45 cable tester Volt ohm Meter 8 10 pan head Phillips screws assorted lengths Wire Nuts and or El...

Page 4: ...nted A 4 Calculate the Required mounting height B Note approximate mounting height can be calculated using the following chart Mounting below 15 feet is not recommmended Note This table is set for the minimum focus length for the camera The zoom can be used to extend the range Example A is 30 feet The camera can be mounted at any of the heights in the table higher the bet ter and zoomed to adjust ...

Page 5: ...a Locate the wires at the camera housing marked 24VAC 15VDC Splice connecting wires to the 24VAC 15VDC power supply Splice the wires to the 24VAC 15VDC connections at the power supply Note The 24VAC Power Supply provided for camera must be connected positive positive neg ative negative NOTICES The Surge protector must be mounted near the MONITOR and all items shown are connected to it This is a to...

Page 6: ...the camera to the monitor 3 Set up and test Monitor Alert parameters see Configure System page 18 NOTICE Any junction boxes or cable routing must be sealed and weather protected OFF ON Surge Protector Camera Cat 5 Coupler Cat 5 Network Cable Supplie by Installer Cat 5 Network Cable Supplie in Kit Cat 5 Crossover Cable Supplied in Camera Housing Parking Spaces Monitor Long Range Systems 5 CurbAlert...

Page 7: ...eo Setup 1 Locate the camera where it will be used and apply power 2 Setup the laptop IP address on the computer being used for the adjustment see Laptop Manual Network Setup on next page 3 Connect the camera network output through the orange or red crossover cable from the camera housing to the computer and apply power to the camera 4 Open Internet Explorer Browser select Address 192 168 0 100 Th...

Page 8: ...Use Live Video to adjust camera 8 When finished with camera adjustment return Laptop to normal network mode and connect cam era to system for final setup Long Range Systems 7 CurbAlert User Manual ...

Page 9: ... Windows being used 1 From Settings Menu select Local Area Connection 2 Select Properties 3 Highlight Internet Protocol TCP IP then select Properties Note Before changing make note of the TCP IP properties of the local area connection so they may be reset when done 4 Select Use the Following IP address 5 Set the manual properties as shown IP Address 192 168 0 254 Subnet mask 255 255 255 0 Default ...

Page 10: ...to normal settings Note This procedure may vary slightly de pending upon the version of Win dows being used 2 From Settings Menu select Local Area Con nection 3 Select Properties 4 Highlight Internet Protocol TCP IP then se lect Properties Long Range Systems 9 CurbAlert User Manual ...

Page 11: ...IP address 6 Either select Obtain an IP Address automatically or Reset the manual properties noted in step 3 of the above procedure 7 Select Okay until returned to normal display screen Long Range Systems 10 CurbAlert User Manual ...

Page 12: ...r to the camera 3 Route and connect signal cable from the router to the monitor 4 Set up and test Monitor Alert parameters see Configure System page 12 5 Connect the user s local network to the system used primarily for obtaining updates OFF ON Surge Protector Camera Cat 5 Coupler Cat 5 Network Cable Supplie by Installer Cat 5 Cable From Basic Kit Cat 5 Crossover Cable Supplied in Camera Housing C...

Page 13: ...e pass code to enable the setup menus Four screens are used for setup Each is enabled by selecting the CONFIGURE button at the main viewing screen Setup consists of three functions 1 System sets basic camera network and timing goals 2 Paging sets up server manager and duty pagers 3 Schedule sets intervals for periodic paging Zones is used to define the detection zones Tune video sets the detection...

Page 14: ...e assigned Camera IP address The IP address for the Sony camera is 192 168 0 100 The Use ActiveX box must NOT be checked This is used for the crossover direct connection If an IP address must be assigned a network director usually as signs this address the camera must be setup for this address using the camera adjustment program see page 4 Resolution The resolution buttons are not used with this c...

Page 15: ...xceeded and periodic updates of system status Server pager this is the number of the pager assigned to the server who is tasked with greet ing the curbside customer Duty Pager these are numbers assigned to people who may do periodic tasks e g refill the napkin dispenser etc Paging delays Paging Delays in seconds Car in Lane how long a car is detected before the server is paged Greet Time Page how ...

Page 16: ...ing to manager and duty pagers Manager Paging Enables sets the interval and time period for sending the manager updates of average greet times and serv ing times Duty Paging Enables sets the interval and time period for sending the duty person a reminder message to perform a pe riodic duty ...

Page 17: ...reen is used to assign the detection zones Alert Zone Setup This is the zone where arriving traffic will alert staff 1 Select the zone desired Z1 Z6 2 Press the Assign button 3 Touch to select the zone outline 4 Press the Save button 5 The zone outline will be shown ...

Page 18: ...l be shown 6 The Zone Size slider adjusts the zone size for greater sensitivity this should be as small as pos sible Note The area where the greet zone is selected should be marked to show greeters where to walk to set off the Greet detection Several zones can be stacked to detect if greeters walk through a selected area if multi cars have arrived this will show all Alert zones as greeted Long Ran...

Page 19: ...sults 1 Clear the target area 2 Set for LIVE 3 Press the Reload button 4 Adjust the Threshold slider until the zones are clear of any distortions 5 Move a vehicle into the space and be sure the target area is highlighted 6 Remove the vehicle and be sure the target area clears Stop and Start restart the camera Reload is used if the area is clear of targets Return to the Curb Alert tab Long Range Sy...

Page 20: ...s used to determine usage and other report information This is also re quired in the event a field upgrade is required Backup sends the data to LRS for identification A High Speed Internet connection is required Restore is used to contact LRS database to restore system settings A High Speed Internet connection is re quired Long Range Systems 19 CurbAlert User Manual ...

Page 21: ...unt the transmitter in a location near the Monitor It is optional to use the Velcro provided 3 Connect the Serial cable to the Monitor and then connect the stereo plug into the OEM transmit ter 4 Connect the Antenna to the transmitter 5 Plug power supply into an electrical outlet Long Range Systems 20 CurbAlert User Manual Serial Cable Supplied in Kit Electical Outlist or Surge Protector 5V DC Pow...

Page 22: ...supplies call Long Range Systems at 800 437 4996 Monday through Friday 8 30 am to 5 00 pm Central Time For weekend or night emergencies Long Range Systems has 24 7 live technical support available Please keep in mind that options are limited over the weekend Long Range Systems 21 CurbAlert User Manual ...

Page 23: ...particular purpose nor does LRS Inc assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages Typical parameters that may be provided in LRS Inc data sheets and or specifications can and do vary in different applications and actual performance may vary over t...

Reviews: