2.4 Intended use
The system has been developed especially for micro material processing and
approved for the following processing procedures and materials:
Processing procedures
Processing of single-sided and double-sided base material
Processing of multi-layer material
Processing of SMD solder paste stencils
Processing of solder stop films
Engraving of signs or housing panels (e.g. front or rear plates)
Drilling of plane materials using drilling tools
Materials
GFRP or CFRP base material
PTFE or ceramic-filled base material
non-ferrous metals like
aluminum acc. to DIN EN 573:EN AW-6012
brass acc. to DIN EN 1412:CW603N
plastics like
polyoxymethylene
ABS copolymers
Necuron ®
The system may only be used for the processes and materials listed in this chapter. If
in doubt, contact the LPKF Service for alternative materials or processes.
The system is designed for a service life of 10 years used in one-shift operation (8
hours a day, 5 days a week).
The system is intended for use in a laboratory environment.
Only control the system with the system software that is included in the scope of
delivery. The system may only be operated with a sufficiently dimensioned extraction
system that includes a fine particle filter and active carbon filter. LPKF recommends
the LPKF extraction system with integrated HEPA filter and activated carbon filter.
In case of doubt contact the LPKF Service to receive more information on alternative
materials or processing procedures.
Only control the system with the system software that is included in the scope of
delivery.
The system may only be operated with an extraction system that is sufficiently
dimensioned.
Contact the LPKF sales department or your local representative if you plan to use
another extraction system.
Only use qualified and approved extraction systems.
Any other kind of use is considered as not intended . The manufacturer is not liable for
any damage resulting from this, the operator alone bears the risk. Part of the intended
use is also to follow the instructions for safety in this user manual with regard to
operation and maintenance of the system.