background image

  

  Doc:MSGB102A0205.doc                                               15/07/11                                                                               P. 19/20       

 

3. System 

connection 

 

Connect the GSM modem programmed at point 1 with the ATL  via cable code 51C7 

 

Connect the second modem to the PC using the standard cable provided with the modem 

 

Power the GSM modem and wait 30 seconds for initialisation 
 
 

4.  Configuration of the ATL Remote control program 

 

Start the ATL Remote control program from the PC with the modem already connected and powered. 

 

Choose the 

Configuration-Options 

menu 

 

Set the 

Connection via modem 

box from the 

General

 table. 

 

If the 

Modem index 

table is empty, enter a record with the name of the installation and the phone number 

corresponding with the telephone line of the modem connected to the ATL. 

 

Click on 

OK

 to close and save the 

Options 

window 

 
 

5. Online 

Connection 

 

Choose 

Call with modem 

from the 

Communication  

menu

 

 

From the drop-down box choose the name of the installation to be called. The corresponding telephone 
number (previously loaded in the 

Modem index

) will be shown in the box below.

 

 

Click on 

Dial 

 

At this point, the modem at the PC end calls the ATL modem. After a few rings the ATL modem and the 
program switch automatically to the online mode.

 

 

To end the connection, choose 

Modem-hang up 

from the 

Communication

 menu

 

 

In the event of problems… 

If during the attempted call the GSM modem connected to the ATL does not ‘ring’, this means that the call 
fails to reach its destination. In this case, carry out the following checks: 

 

Check that the signal near the GSM modem is strong enough ( > 40%).  To do this, use the PM.EXE 
program. 

 

Check that the PC modem is powered and connected with the cable to the correct serial port (the one 
set in 

Configuration-Options-Serial port

 
If the modem called rings repeatedly but the connection fails to be established (the window with the wording 
‘Connection OK' is not shown): 

 

Check  the ATL programming (see previous point 2) 

 

Check  the ATL-modem cable 51C7 

 

If you are using a phone line passing through a switchboard, try to use a direct line. Some switchboards 
‘alter’ the phone call and make it unrecognizable by the GSM modem. 

 
 
If the PC shows the wording 'Connection OK'  but then the program goes Offline: 

  Check  the quality of the GSM signal  

 

Try connecting directly from the PC to the ATL with cable 51C2 and carry out all the checks described in 
the ‘Direct RS-232 connection’ chapter 

 

Check  that the GSM modem is programmed correctly as described in the previous point 1  

 

Summary of Contents for ATL10

Page 1: ...485 connection 3 Modem connection 3 Main window 4 System configuration 6 Password 9 Real Time Clock setting 9 Access to Setup menus 10 Online Programming 10 Offline Programming 10 Setup menu 11 Modem parameters 12 View menu 13 Front panel 13 Statistic data 15 Input Outputs 15 Keyboard lock Unlock 15 Appendix A Remote control through modem 16 Connection via standard modem 16 Connection via GSM mode...

Page 2: ...5 98 2000 XP Vista 7 operating system Graphic card with 1024x768 or higher resolution A free standard RS232 serial interface COM 64Mb of RAM Pentium class or higher processor CD ROM drive for installation Installation To install the software you need a PC with the operating system already installed and running and the program setup CD You should also have at least a basic knowledge of the PC and b...

Page 3: ... address 01 Make sure that the PC speed an parity settings match the ATL RS 485 setting 4 6 4 7 4 5 4 4 4 2 4 3 4 1 RS485 B 6 2 A 6 3 SG 6 1 RS232 9 4 N 9 2 9 3 L3 L2 9 1 L1 VOLTAGE INPUTS LINE 1 220 240V AC SUPPLY DIGITAL INPUTS DC SUPPLY 5 2 5 3 5 1 50 60 Hz 100 690VAC L2 8 3 L3 L1 8 2 8 1 7 3 7 2 0V 7 1 100 690VAC 50 60 Hz INPUTS DIGITAL SG B A TR RS485 TR RS485 SG B A 3 3 250V 5A 250V 5A AC1 B...

Page 4: ...modifiable password at the first setting the default password is LOVATO The following are displayed in the main window Voltage and frequency of both Line 1 and Line 2 sources Switching devices status ATL supply status Alarm status Lastly the following are indicated from left to right on the status bar close to the lower edge of the main window Model and release of the internal firmware of the ATL ...

Page 5: ...ent ATL operating mode Device model and software revision Displays the event log window Drop down box to select the controller in RS 485 multi drop networks Displays statistic data Real time clock setting Displays Inputs Outputs status Utility genset icon Voltage readings Frequency reading Line status indicators Switching device status indicators In MAN mode double clicking on this box will initia...

Page 6: ...to pay attention to the setting of each ATL connected to the network Before proceeding with the explanation of the various functions of the software we will examine the configuration window looking at the meaning of all settings Configuration Options General In the general window there are some generic setting of the software Particuar attention must be paid to the serial port setting that must be...

Page 7: ...e to each of them In case one controller is not to be accessed it is possible to disable it using the dedicated checkbox Add a new ATL to the network configuration Removes the last ATL from the network configuration Selects the previous next ATL Description of the ATL It is used to identify the controller in the main page data log events and more Total number of configured ATLs Selected ATL Enable...

Page 8: ... from this list For each installation it is possible to define if one or more units are installed and associate an initial page to be loaded once connection has been established To enter a new record first click on New fill the fields and then click on Add To eliminate a record first select it in the table then click Remove button Installation code They must all be different Description of install...

Page 9: ...et MAX values event log operation counters etc Password After the first installation the password is LOVATO Later the user will be able to customize its password using the New Password button and then entering the new desired password two times New password Real Time Clock setting To view and set the RTC real time clock of the ATL click on the dedicated icon on the toolbar The following window wil...

Page 10: ...ol units with the same settings or in order to maintain a master file of the original settings of a system Online Programming When the PC is connected to a device Online mode the parameter transfer is always done from to the device internal memory In this mode the user can View and modify the parameter values into the device menu Parameters Edit setup parameters then use buttons Transmit and Recei...

Page 11: ...ter Parameter description Setting of the parameter Highlighted in yellow if different from the factory set default value Double clicking on this box the parameter can be set using the numeric keypad Graphic bar Drag this with the mouse to modify the setting Scroll down box with possible options Transmits the values displayed in the window to the ATL and saves them Enabled only in online mode with ...

Page 12: ... possible to make the ATL send SMS messages or send electronic mail messages still as a result of an alarm or when a fixed interval of time has elapsed note that sending E mails through an SMS is a service supplied only by some phone companies The window shown below contains all the parameters needed to perform the above mentioned functions Modem general enable AutoCall enable Choice of type of mo...

Page 13: ...ulti drop network in the title bar of the window it is reported the name of the unit currently selected Clicking with the mouse on the keys after having entered the password you can select the measurements and functions in the same way as on the physical device However you cannot access those functions such as parameter programming reset statistics etc that require simultaneous pressing and or hol...

Page 14: ...ory so it is kept even without power supply Events include Source lines present not present Switching devices opening closing Alarms begin and end Change of operation mode Change of setup parameters Remote communication on off Power supply on off Clear events history Available only after entering the password Export to ASCII file Print event history Close Event log window Event time stamp Event nu...

Page 15: ...shows the function programmed on ATL Input Output terminals and their current status Please note that for the output relays the status shown is the status of the relay coil energized not energized that sometimes is opposite to the logic function of the relay example global alarm relay energized conditions ok Keyboard lock Unlock Using this function it is possible to lock or unlock the front panel ...

Page 16: ...onnect it to the ATL The PM EXE program transmits the following configuration string to the modem AT E0 N6 U6 W0 CR commands valid for modem model 5630 If the user is familiar with terminal emulation programs such as Windows Hyperterminal this programming can be done manually without the aid of the PM EXE program In this case it will be necessary to set the serial interface at 9600 Baud 8 bit No p...

Page 17: ...up from the Communication menu In the event of problems If during the attempted call the modem connected to the ATL does not ring this means that the call fails to reach its destination In this case carry out the following checks Try dialing the telephone number of the line to which the ATL is connected using a normal telephone The modem called should give off sounds that ought to be heard in the ...

Page 18: ...rd cable Then start the PM EXE program supplied together with this software and press the GSM modem program button Wait for the confirmation message and then disconnect the GSM modem from the PC Important A SIM CARD enabled for data transmission is needed to make the GSM modem work A normal SIM CARD for cell phone does not work if used with the GSM modem Contact the SIM CARD Supplier to have it en...

Page 19: ...dem and the program switch automatically to the online mode To end the connection choose Modem hang up from the Communication menu In the event of problems If during the attempted call the GSM modem connected to the ATL does not ring this means that the call fails to reach its destination In this case carry out the following checks Check that the signal near the GSM modem is strong enough 40 To do...

Page 20: ...ssing of ON OFF Line2 button PWD password Enters the access password The commands can be chained and spaced by a pause To enable the execution of SMS commands it is necessary to enable the corresponding box in the Modem Parameters window see Modem Parameters chapter In the same window the user has to specify the password intended to be used As mentioned previously if the cell phone used to send th...

Reviews: