background image

INTERCONNECTION DIAGRAM

 CONNECTING LOUROE MODEL AOPSP-PB 

DIRECTLY TO AN IP CAMERA, DVR, 

VIDEO SERVER, ETC. USING 3-COND. SHIELDED CABLE

 

EXT 
MIC

SPKR

+12Vdc

AUDIO
  OUT

AUDIO

   IN

A B C

TALKBACK
ADJUST

MIC

ADJUST

C

A

SP

B

LOUROE MODEL  AOPSP-PB

WHITE (SP)

BLACK (C)

(C) BARE

(B) RED

TO AUDIO OUT OF IP CAMERA, DVR, ETC.

TO AUDIO IN OF IP CAMERA, DVR, ETC.

NOTE: BLACK AND BARE WIRES ARE COMMON GROUND

BARE (C)

BLACK (C)

RED (B)

4-PIN TERMINAL BLOCK IDENTIFIER OF AOPSP-PB (A,B,C,SP)

(

)       B = Audio Output 

(

)     C = Ground (audio) and Ground (speaker) (black wire)

(

) SP = Speaker output 

 A = not used with this application

red

bare
white

West Penn 358
or equivalent

C

A

SP

B

WHITE (SP)

Audio Out

Audio Out

Audio In

Audio In

Bare Wire

Red Wire

RCA CONNECTION

3.5mm  MONO CONNECTION 

3.5mm  STEREO CONNECTION 

White Wire

Black Wire

Black Wire

White Wire

Red Wire

Bare Wire

M
O

N

O

S

T

E
R
E

O

Audio Out

Audio In

Red Wire

Black Wire

White Wire

Bare Wire

WIRING REQUIREMENTS

 3 Conductor consisting of:

+

2 Conductor 

shielded

, 20  gauge 

with 22 gauge drain 

+

1 Conductor 

unshielded

, 20 gauge 

All in the same jacket

CALL 

BUTTON

ELECTRET

CONDENSER

MICROPHONE

GREEN 

WIRE

WIRE 

NUT

WIRE 

NUT

TO SWITCH CLOSURE OF

AUDIO RECEIVING DEVICE

(refer to manufacturer’s

instructions for connection)

EXT 
MIC

SPKR

AUDIO
  OUT

AUDIO

IN

AOP-XD is not used for this application.

+12Vdc,500mA  power required
(AD-1 power supply included)
Connect to this 2-pin terminal block

12 Vdc power is required to connect the AOP-SP-E directly to 
an IP camera or DVR such as AD-1 power supply. 
     Positive 12Vdc connects to terminal marked “+”
    Negative 12 Vdc or ground 
 

connects to terminal marked “GND”    

                 

(wire with white stripes)

+12Vdc

+

GND

Page 4 of 8

LOUROE  ELECTRONICS®    6 9 5 5   VA L J E A N   AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

website: www.louroe.com                          e-mail: [email protected]

   

   

(818)

INSTALLATION AND OPERATING INSTRUCTIONS

aopsp-pb 03/11

Summary of Contents for AOPSP-PB

Page 1: ...for flush or surface mounting to a wall or flat surface Back Boxes Flush Mount Plastic Surface Mount Steel The gain of the microphone and speaker are factory adjusted If it is necessary to change the gain of either or both the audio output of the microphone and speaker of the unit it has to be done in small increments For adjusting the gain of the microphone rotate clockwise to increase or counter...

Page 2: ...a 24V 1A Power Supply First connect small end to the 24Vdc jack located on the back panel of AOP XD Then plug large 2 prong power block into a standard 120V electrical outlet or power strip Green LED on front panel will illuminate indicating unit is powered Model AOP XD will send power to the remote AOPSP PB Call Station For instructions regarding the functions of AOP XD refer to accompanying AOP ...

Page 3: ...panel INTERCONNECTION DIAGRAM BETWEEN LOUROE MODEL AOPSP PB AND AOP XD AUDIO TRANSCEIVER INTERFACE INPUT AUDIO OUTPUT A U D I O P A T H A U D I O P A T H RCA Plug Color Code of recommended wiring is RED 12Vdc power to microphone BLACK Audio Output BARE Ground microphone WHITE Speaker 24Vdc 1A POWER SUPPLY INCLUDED WIRING REQUIREMENTS 3 Conductor consisting of 2 Conductor shielded 20 gauge with 22 ...

Page 4: ...O S T E R E O Audio Out Audio In Red Wire Black Wire White Wire Bare Wire WIRING REQUIREMENTS 3 Conductor consisting of 2 Conductor shielded 20 gauge with 22 gauge drain 1 Conductor unshielded 20 gauge All in the same jacket CALL BUTTON ELECTRET CONDENSER MICROPHONE GREEN WIRE WIRE NUT WIRE NUT TO SWITCH CLOSURE OF AUDIO RECEIVING DEVICE refer to manufacturer s instructions for connection EXT MIC ...

Page 5: ...otal including flange 6 H x 8 W x 2 D metric 158mm H x 203mm W x 67mm D metric 127mm H x 175mm W x 67mm D metric 158mm H x 203mm W x 70mm D Page 5 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 INSTALLATION AND OPERATING INSTRUCTIONS SPECIFICATIONS Mechanical aopsp pb 03 11 IMPORTANT NOTICE When...

Page 6: ... appear within one year 12 months from date of shipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation misuse accident or in violation of...

Page 7: ...STALLATION AND OPERATING INSTRUCTIONS Page 7 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 aopsp pb 03 11 ...

Page 8: ...MANUFACTURED IN THE Page 8 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 aopsp pb 03 11 ...

Reviews: