INTERCONNECTION DIAGRAM
CONNECTING LOUROE MODEL AOPSP-PB
DIRECTLY TO AN IP CAMERA, DVR,
VIDEO SERVER, ETC. USING 3-COND. SHIELDED CABLE
EXT
MIC
SPKR
+12Vdc
AUDIO
OUT
AUDIO
IN
A B C
TALKBACK
ADJUST
MIC
ADJUST
C
A
SP
B
LOUROE MODEL AOPSP-PB
WHITE (SP)
BLACK (C)
(C) BARE
(B) RED
TO AUDIO OUT OF IP CAMERA, DVR, ETC.
TO AUDIO IN OF IP CAMERA, DVR, ETC.
NOTE: BLACK AND BARE WIRES ARE COMMON GROUND
BARE (C)
BLACK (C)
RED (B)
4-PIN TERMINAL BLOCK IDENTIFIER OF AOPSP-PB (A,B,C,SP)
(
) B = Audio Output
(
) C = Ground (audio) and Ground (speaker) (black wire)
(
) SP = Speaker output
A = not used with this application
red
bare
white
West Penn 358
or equivalent
C
A
SP
B
WHITE (SP)
Audio Out
Audio Out
Audio In
Audio In
Bare Wire
Red Wire
RCA CONNECTION
3.5mm MONO CONNECTION
3.5mm STEREO CONNECTION
White Wire
Black Wire
Black Wire
White Wire
Red Wire
Bare Wire
M
O
N
O
S
T
E
R
E
O
Audio Out
Audio In
Red Wire
Black Wire
White Wire
Bare Wire
WIRING REQUIREMENTS
3 Conductor consisting of:
+
2 Conductor
shielded
, 20 gauge
with 22 gauge drain
+
1 Conductor
unshielded
, 20 gauge
All in the same jacket
CALL
BUTTON
ELECTRET
CONDENSER
MICROPHONE
GREEN
WIRE
WIRE
NUT
WIRE
NUT
TO SWITCH CLOSURE OF
AUDIO RECEIVING DEVICE
(refer to manufacturer’s
instructions for connection)
EXT
MIC
SPKR
AUDIO
OUT
AUDIO
IN
AOP-XD is not used for this application.
+12Vdc,500mA power required
(AD-1 power supply included)
Connect to this 2-pin terminal block
12 Vdc power is required to connect the AOP-SP-E directly to
an IP camera or DVR such as AD-1 power supply.
Positive 12Vdc connects to terminal marked “+”
Negative 12 Vdc or ground
connects to terminal marked “GND”
(wire with white stripes)
+12Vdc
+
GND
Page 4 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
INSTALLATION AND OPERATING INSTRUCTIONS
aopsp-pb 03/11