background image

BARE

A B C

BACKSIDE OF

VERIFACT

 A

MICROPHONE

L

N

BLACK

RED

A

B

C

BLACK

BARE

RED

TO LOUROE™ BASE STATION

OR

TO OTHER LOUROE AUDIO RECORDING DEVICES

(IF-1, IF-2, IF-4, IF-8 ETC.)

A  =  +12Vdc (RED)
B  =  Audio     (BLACK)
C  =  Ground (BARE)

2 Conductor 

shielded

 cable, 22 

gauge with a 24 gauge drain 
wire.

NOTE:

Unshielded cable is not 

satisfactory for audio 
systems.

WIRING REQUIREMENTS

 MICROPHONE SENSITIVITY SWITCH

The microphone pre-amp (PC board) contains a sensitivity 
switch with two positions marked N and L, and is located on the 
back side of the Model A near the terminal block:

 

N represents normal sensitivity 
(0 dB @ 1,000

)

L represents lower sensitivity 
(-6 dB @ 1,000

)

Microphone is always shipped in the N position.  For less 
microphone sensitivity, move slide switch to L position.  

INSTALLATION AND OPERATING INSTRUCTIONS

Page 3 of 4

LOUROE  ELECTRONICS    6 9 5 5   VA L J E A N   AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

website: www.louroe.com                          e-mail: [email protected]

   

   

(818)

®

A_mic-inst_4/11

Summary of Contents for VERIFACT A

Page 1: ...for outdoor use or in areas with high moisture content VERIFACT A Microphone Housing and pre amp Microphone Element 2 Conductor shielded cable 22 gauge with a 24 gauge drain wire NOTE Unshielded cable is not satisfactory for audio systems WIRING REQUIREMENTS DESCRIPTION SPECIFICATIONS Sensitivity microphone preamp Frequency response Output Current drain 80 dB SPL input provides 0 254V rms 40 Hz to...

Page 2: ...closer to the customer rather than the cash register as the drawer sound could dominate the recording It should be installed closest to the area to be monitored and documented 3 Avoid installing microphone near air vents air conditioners fans and other equipment that generate high sound and air pressure 4 If microphone is installed in a police interview room room should be conditioned with any typ...

Page 3: ...CH The microphone pre amp PC board contains a sensitivity switch with two positions marked N and L and is located on the back side of the Model A near the terminal block N represents normal sensitivity 0 dB 1 000Ω L represents lower sensitivity 6 dB 1 000Ω Microphone is always shipped in the N position For less microphone sensitivity move slide switch to L position INSTALLATION AND OPERATING INSTR...

Page 4: ... the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship Should a defect appear within one year 12 months from date of shipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS This warranty doe...

Reviews: