background image

TROUBLESHOOTING

II.

  No audio present.

a. 

 Using a DC Voltmeter, check the voltage across terminal “A” and “C” (”A” positive; “C” ground) of the Mic 3-Pin 

Terminal Block

[12]

.  It should read 12V.  The microphone requires 12Vdc to work.

1)

  Check connections to the microphone.

b.

  Remove the wire connected to the “B” terminal of the Mic 3-Pin Terminal Block.  Using an AC meter (set to 

lowest voltage range), check the presence of audio from the microphone.  Place the meter leads between wire 
removed (positive) and terminal “C” (ground).  Generate some loud noise close to the remote microphone 
while observing the meter reading.  If audio is present, the meter reading will start to fluctuate.  If there is no 
movement, the remote microphone is defective.  Call factory for assistance.

Factory assistance is available between 8:30 AM to 4:00 PM Pacific time.  Call (818) 994-6498.

INSTALLATION AND OPERATING INSTRUCTIONS

Page 7 of 8

LOUROE  ELECTRONICS    6 9 5 5   VA L J E A N   AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

website: www.louroe.com                          e-mail: [email protected]

   

   

(818)

®

SPECIFICATIONS - Verifact   A 

Frequency response

Output

Current drain

40 Hz to 15 kHz ± 1 dB

10 mA

Supply voltage

12 Vdc

Microphone housing

High impact anti-static ABS

Dimensions                   

Weight

Weight (Shipping) of kit

4”

"

 dia  x  1 ½ H 

3.5 oz

4 lbs

Line Level (0dBV, 600

?

 

@ 1kHz)

SPECIFICATIONS (AP-8)

Monitor power output

1W @ 8

Audio input impedance

10k

Freq. response 

100 Hz to 10kHz

Power input

12 Vdc, 500mA

Dimensions

6 5/8"W x 8 5/8  x 2 1/8"H

"L

Headphone impedance

Current Drain

8 to 600 

200mA

Weight

1lb 7oz

Audio output impedance

1K

?

®

ask4_108_inst_1/15

Type

Electret Condenser

Summary of Contents for ASK-4 108

Page 1: ...microphone that produces line level audio output AUDIO MONITORING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS 6955 VALJEAN AVE VAN NUYS CA 91406 PH 818 994 6498 FAX 818 994 6458 www louroe com techsupport louroe com Page 1 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 ask4_108_inst_1 15 ASK ...

Page 2: ... is necessary to monitor more than one zone at a time but audio may be difficult to understand if there is audio activity at several zones Zone switches light blue when press indicating active zone 3 Headset Jack Used for private listening Any stereo headset with 8 to 600W impedance maybe used Mutes speaker output when use 4 Power Indicator Lights green when power is turned ON 5 Power Volume Knob ...

Page 3: ...ed when a headset is connected to Headset Jack 3 8 Audio In Jack RCA Receives audio playback from DVR VCR etc and is broadcast through the built in speaker 7 9 Audio Out Jack RCA Provides audio to DVR VCR for recording or to other audio devices accepting line level input when any of the Zone Selector Switches 2 are activated or push in The audio output to this jack will be the audio selected by th...

Page 4: ...a VCR or to a DVR with one audio input 1 Connect an RCA cable to the Audio Out jack 9 of AP 8 and connect other end to Audio In or line in of VCR DVR 2 To record press the Zone Selector Switch 1 located on front panel of base station for the audio zone to be recorded 3 For audio playback connect another RCA cable from Audio Out or line out of VCR DVR to Audio In 8 of AP 8 4 Press in the Play Mute ...

Page 5: ...ATION A B C C B A A B C C B A A B C C B A A B C C B A 1 2 3 4 5 6 7 8 IN OUT N L A B C C B A Red A Black B Bare C Red A Black B Bare C Red A Black B Bare C 12Vdc SELECTABLE AUDIO OUTPUT Use if recording device has only one Audio Input Use for audio playback from recording device WIRING REQUIREMENTS VERIFACT A MICROPHONE CONNECTIONS ARE SIMILAR TO AP 2 AND AP 4 REAR OF AP 8 BASE STATION 2 Cond Shie...

Page 6: ...he rear of the unit With a DC voltmeter check that 12 Vdc is present at terminals A and C If voltage is not present unit has a problem with its power supply If voltage is present check to assure that wires are connected properly to the right terminals Otherwise microphone is defective Call factory for assistance 3 Repeat step 2 for the remainder of the zones 4 When a recorder is connected to the u...

Page 7: ...rophone is defective Call factory for assistance Factory assistance is available between 8 30 AM to 4 00 PM Pacific time Call 818 994 6498 INSTALLATION AND OPERATING INSTRUCTIONS Page 7 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 SPECIFICATIONS Verifact A Frequency response Output Current dra...

Page 8: ...ment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship Should a defect appear within one year 12 months from date of shipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS This warranty does not extend to a...

Reviews: