Lotus FTLD-85GS Installation And Operating Instructions Manual Download Page 7

GENERAL INFORMATION

Translation of the original instructions

7

2 GENERAL INFORMATION

2.1

Declaration of compliance

The manufacturer declares that the appliances comply with the requirements of the regulation GAR
2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be
performed in compliance with current regulations, especially with regard to ventilation of the premises and
the exhaust gas evacuation system.
 

·

Read the warnings in this manual carefully. They provide important information about safe installation,

use and maintenance.

·

The instruction manual must be kept for the entire duration of the equipment and made available to users

for every possible consultation. The manual should be consulted for any information concerning
installation, use and maintenance of the appliance.

·

After removing the packaging, check the integrity of the equipment.

·

All packaging materials (plastic bags, polystyrene, staples, etc.) must be disposed of in compliance with

current regulations.

·

Before connecting the appliance, make sure that the information on the data plate matches the electricity

and gas mains where the appliance is installed. The manufacturer accepts no liability if the
equipment is not connected in accordance with current regulations.

·

Always keep all parts of the equipment clean to avoid the risk of oxidation/rust and/or aggression by

chemical agents.

·

The equipment must only be used by personnel trained for the purpose.

·

The installation must be implemented by professionally qualified personnel in accordance with

the manufacturer's instructions and current reference standards.

·

The electrical safety of this equipment is only ensured when it is correctly connected to an effective

ground/earth system as required by current electrical safety standards. The manufacturer cannot be held
liable for any damage caused if the system is not connected to ground/earth.

·

Before carrying out any cleaning or maintenance tasks on the equipment, unplug it from the electricity

mains. In the event of faults or malfunctions, always deactivate the appliance.

·

Repair work of any kind must only be performed by qualified personnel.

·

This appliance must only be used for its expressly intended purpose for cooking or heating food. Any

other use is considered improper.

·

The appliance is intended for professional use and must be used by trained personnel.

·

The installation and possible transformation to another power supply voltage (if envisaged), or

transformation for operation with another type of gas, must be implemented exclusively by qualified and
authorised professional personnel.

·

Before using the appliance, carefully clean all surfaces intended to come into contact with food.

·

The manufacturer declines any and all liability for any direct or indirect damage resulting from improper

use of the equipment. The manufacturer declines any and all liability for damage caused by incorrect
installation, tampering, poor maintenance and unskilled use. Moreover, the manufacturer declines any
liability for possible inaccuracies that may be contained in this booklet attributable to errors in
transcription or printing and equally reserves the right to make any changes to the product it deems
useful and/or necessary without compromising its essential characteristics.

·

The manufacturer cannot be held liable for any damage caused by failure to comply with these

basic standards and all other use and maintenance standards contained in this booklet.

Summary of Contents for FTLD-85GS

Page 1: ...NAL USE FTLD 85GS FTRD 85GS FTLD 87GS FTLRD 87GS FTRD 87GS FTLD 89GS FTLRD 89GS FTRD 89GS FTLD 95GS FTRD 95GS FTLD 99GS FTLRD 99GS FTRD 99GS Model LIBR ISTR FTD G Code 563047000 Review 1 Edition date...

Page 2: ...ation 9 3 4 Electrical gas connections 9 3 5 Water connection and drainage 14 4 BURNERS TECHNICAL DATA TABLE ITGB 15 4 1 Burners technical data table 15 5 INSTRUCTIONS FOR USE 16 5 1 General informati...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FTD G...

Page 4: ...E mm AIR INPUT cm FT D 85G 500 800 597 5 77 3 105 150 FT D 87G 700 800 597 5 77 3 105 220 FT D 89G 900 800 597 5 87 1 450 300 FT D 95G 500 950 719 77 3 105 345 FT D 99G 900 950 719 87 1 450 490 B Elec...

Page 5: ...ation of the original instructions 5 1 2 Components FIG A 1 Valve knob 2 Dashboard bracket 3 Piezoelectric 4 Valve 5 Gas pipes 6 Extends drainage 7 Pilot 8 Ignition spark plug 9 Injector 10 Bracket 11...

Page 6: ...Translation of the original instructions 6 FIG B 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage WIRING DIAGRAM FTDG 1 Power supply terminal board 2 Power button 3 4 Ignition...

Page 7: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 8: ...llection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 201...

Page 9: ...nding the heat emitted by this appliance Connect the water supply if necessary Caution Do not install the appliance near equipment machines used in cold processes If the appliance has to be installed...

Page 10: ...lls made of flammable material furthermore appropriate measures should also be adopted to ensure the thermal insulation of flammable parts such as the installation of heat shields take special care to...

Page 11: ...es this gas To adapt the appliance to another type of gas make sure that the type of gas in question complies with the information in this instruction manual Warning Pressure is measured with a pressu...

Page 12: ...standard In the case of forced evacuation The gas supply to the appliance must be directly servo controlled by the system and must stop if the flow rate drops below the values indicated in point 4 3...

Page 13: ...the original instructions 13 1 Windproof fume stack fig 3 Extractor hood fig 4 2 Servo system B11 type appliances are supplied on request with a hood or a hood and windproof fume stack to be assemble...

Page 14: ...r siphons Water is discharged by free fall so it is essential that the height of the drain is lower than the point of exit of the pipe The water discharge pipe also conveys cooking fat If the drain is...

Page 15: ...h 0 741 FT D 87GS Burner injector 1 100 mm 3 x 87 3 x 87 3 x 135A Pilot injector 1 100 mm 1 x 19 1 x 19 1 x 27 Consumption kg h 0 828 kg h 0 816 m3 st h 1 111 FT D 89GS 2 burner 7 kW Burner injector...

Page 16: ...ody to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation If smoke is emitted...

Page 17: ...ion 0 This control blocks the gas supply to both the main burner and the pilot burner 5 6 Observations and advice In the case of appliances with two cooking zones it is possible to set different tempe...

Page 18: ...dicated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasi...

Page 19: ...ront panel unscrew the gas connection screw couplings and extract the valve bulb then replace the faulty parts and install the new ones in sequence THERMOCOUPLE fig A pos 6 unscrew the pilot burner co...

Page 20: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: