background image

INSTALLATION

Translation of the original instructions

9

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Note

 

The connection cable must have the following characteristics: it must be silicone type (to
withstand temperatures of 180 °C), and must have an appropriate cross-section for the power
of the appliance (see technical data table).

 

EQUIPOTENTIAL

 
The appliance must be connected to an equipotential system. The connecting screw is located on the rear of
the appliance and is marked by the yellow symbol above it.
 

Warning

 

The manufacturer is not liable for and does not indemnify damages caused by incorrect
inadequate installations that do not comply with these instructions.

Summary of Contents for FT T-912ET Series

Page 1: ...ructions PROFESSIONAL ELECTRIC FRY TOPS FT 94ET FT 98ET FT T 94ET FT T 98ET FT 912ET FT T 912ET FT 916ET Model LIBR ISTR FT90E POT Code 563008102 Review 1 Edition date 28 03 2019 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Page 2: ...trical and electronic equipment 7 2 3 Technical data table 7 3 INSTALLATION 8 3 1 Delivery checks 8 3 2 Removing the packaging 8 3 3 Mechanical installation 8 3 4 Electrical gas connections 8 4 INSTRUCTIONS FOR USE 10 4 1 General information 10 4 2 Turning the appliance on off 10 4 3 Emptying the container 10 4 4 Observations and advice 10 4 5 Safety thermostat 11 5 MAINTENANCE 12 5 1 Routine 12 5...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FT 9E A Data Plate B Electrical connection FIG 2 FT T A Data Plate B Electrical connection ...

Page 4: ... 4 WIRING DIAGRAM B 1 Switch 2 Power supply terminal board 3 Heating elements 4 White indicator light 5 Green indicator light 6 Thermostat 7 Safety thermostat MODELS TERMINAL BOARD FT 94ET FT T 94ET B FT 98ET FT T 98ET B B FT 912ET B B B FT 916ET B B B B ...

Page 5: ...INTRODUCTION Translation of the original instructions 5 1 2 Example installation of the appliance ...

Page 6: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Page 7: ...rts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table FT S90E MODEL DIMENSIONS POWER SUPPLY MAXIMUM POWE...

Page 8: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The a...

Page 9: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them secur...

Page 10: ...itching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the desired position between 50 and 300 C the white and green indicator lights will turn on The green indicator light indicates that the appliance is powered The wh...

Page 11: ...mostat The appliance is equipped with a safety thermostat that interrupts the electrical circuit if the temperature of the hotplate exceeds the maximum preset value 420 If this happens the appliance can be restored by pressing the red button on the safety thermostat If the problem occurs again call the service department which will remove the causes ...

Page 12: ...ce and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personnel When replacing the electrical components of the machine and the electrical panels scrupulously follow the technical characteristics for the replacement component indicated on the component itself T...

Page 13: ...al connections and proceed with replacement The thermostat and switch are fastened together by a metal bracket HEATING ELEMENT remove the panel and remove the wires connecting the heating element From the bottom unscrew the housing that contains the heating element and once removed make the replacement Caution WHAT TO DO IN THE EVENT OF FAULTS Close the gas connection cock and or switch off the po...

Page 14: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...