Lotus F18-94ETD Installation And Operating Instructions Manual Download Page 9

GENERAL INFORMATION

Translation of the original instructions

9

2.2

User information, RAEE Directive on waste electrical and
electronic equipment

With regard to the regulatory framework of reference of the European Community, we remind the user of the
following:
 

·

Used AAE (Electrical and Electronic Equipment) products must be collected separately

·

The user can carry out this collection in the RAEE collection systems and return the equipment to the

distributor when purchasing a new one

·

Plus being RoHS compatible, (in accordance with Directive 2011/65/EU on the restriction of the use of

certain hazardous substances in electrical and electronic equipment) the potential effects on the
environment and human health may be due to the misuse of the same equipment or parts of it

·

The symbol

next to the rating plate indicates the obligation of separate collection

·

The penalties provided for in the event of improper disposal of RAEE (Waste Electrical and Electronic

Equipment) are those provided for by the national transpositions of European Directives 2012/19/EU

2.3

Technical data table

Electrical technical data table F S90ETD

MODEL

DIMENSIONS

POWER SUPPLY

MAXIMUM

POWER (kW)

MAXIMUM INPUT

(A)

Silicon POWER

SUPPLY CABLE

F18-94ETD

40x90x90h

400V~3N 50/60Hz

15,95

22,95

5 x 2,5 mm²

F18-94ETDP

40x90x90h

400V~3N 50/60Hz

16,2

24,13

5 x 2,5 mm²

F18-94ETDPS

40x90x90h

400V~3N 50/60Hz

16,55

25,65

5 x 4 mm²

F2/18-98ETD

80x90x90h

400V~3N 50/60Hz

31,9

45,9

5 x 10 mm²

F2/18-98ETDP

80x90x90h

400V~3N 50/60Hz

32,4

48,26

5 x 10 mm²

F2/18-98ETDPS

80x90x90h

400V~3N 50/60Hz

33,1

51,3

5 x 10 mm²

F25-94ETD

40x90x90h

400V~3N 50/60Hz

22,05

31,88

5 x 4 mm²

F25-94ETDP

40x90x90h

400V~3N 50/60Hz

22,3

32,96

5 x 6 mm²

F25-94ETDPS

40x90x90h

400V~3N 50/60Hz

22,65

34,48

5 x 6 mm²

F2/25-98ETD

80x90x90h

400V~3N 50/60Hz

44,1

(22,05 + 22,05)

31,88 + 31,88

5x4 mm²+5x4 mm²

F2/25-98ETDP

80x90x90h

400V~3N 50/60Hz

44,6

(22,3 + 22,3)

32,96 + 32,96

5x6 mm²+5x6 mm²

F2/25-98ETDPS

80x90x90h

400V~3N 50/60Hz

45,3

(22,65 + 22,65)

34,48 + 34,48

5x6 mm²+5x6 mm²

 

Summary of Contents for F18-94ETD

Page 1: ...USE F18 94ETD F18 94ETDP F18 94ETDPS F2 18 98ETD F2 18 98ETDP F2 18 98ETDPS F25 94ETD F25 94ETDP F25 94ETDPS F2 25 98ETD F2 25 98ETDP F2 25 98ETDPS Model LIBR ISTR F90ED Code 563048000 Review 1 Editi...

Page 2: ...ormation RAEE Directive on waste electrical and electronic equipment 9 2 3 Technical data table 9 3 INSTALLATION 10 3 1 Delivery checks 10 3 2 Removing the packaging 10 3 3 Mechanical installation 10...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 9 E A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 1 2 Components FIG B ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Page 5: ...INTRODUCTION Translation of the original instructions 5 WIRING DIAGRAM C A Oil basin on the floor B Oil drain cock closed C Oil drain cock open D Oil basin in the guideway E Heater lowered...

Page 6: ...Fan motor 9 1 USB socket 10 3 Grill resistor 11 1 Electronic hardware control board 12 1 Touch electronic board 13 1 Liquid presence sensor 14 2 Remote control switch 15 3 K thermocouple 16 1 Single...

Page 7: ...INTRODUCTION Translation of the original instructions 7 1 3 Example installation of the appliance...

Page 8: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 9: ...ent of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical t...

Page 10: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 11: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 12: ...body to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with...

Page 13: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 14: ...el disconnect the two probe contacts and unscrew the fastening coupling Now from inside the tank unscrew the bulb holder bracket and slide out the probe PUMP Remove the front panel and the rear sectio...

Page 15: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: