Lotus F10T-63EM Installation And Operating Instructions Manual Download Page 9

GENERAL INFORMATION

Translation of the original instructions

9

2.2

User information, RAEE Directive on waste electrical and
electronic equipment

With regard to the regulatory framework of reference of the European Community, we remind the user of the
following:
 

·

Used AAE (Electrical and Electronic Equipment) products must be collected separately

·

The user can carry out this collection in the RAEE collection systems and return the equipment to the

distributor when purchasing a new one

·

Plus being RoHS compatible, (in accordance with Directive 2011/65/EU on the restriction of the use of

certain hazardous substances in electrical and electronic equipment) the potential effects on the
environment and human health may be due to the misuse of the same equipment or parts of it

·

The symbol

next to the rating plate indicates the obligation of separate collection

·

The penalties provided for in the event of improper disposal of RAEE (Waste Electrical and Electronic

Equipment) are those provided for by the national transpositions of European Directives 2012/19/EU

2.3

Technical data table

Electrical technical data table F S60E

MODEL

DIMENSIONS

POWER SUPPLY

MAXIMUM

POWER (kW)

MAXIMUM INPUT

(A)

Silicon POWER

SUPPLY CABLE

F10T-63EM

30x60x29h

230V~ 50/60 Hz

3,65

15,65

3 x 2,5 mm²

F10T-63ET

30x60x29h

400V~3N 50/60 Hz

7,15

10,36

5 x 1,5 mm²

F2/10T-66EM

60x60x29h

230V~ 50/60 Hz

7,3

31,3

3 x 6 mm²

F2/10T-66ET

60x60x29h

400V~3N 50/60 Hz

14,3

20,72

5 x 2,5 mm²

F13-64ET

40x60x90h

400V~3N 50/60 Hz

10,95

15,8

5 x 2,5 mm²

 
Transformation

MODEL

DIMENSIONS

POWER SUPPLY

MAXIMUM

POWER (kW)

MAXIMUM INPUT

(A)

Silicon POWER

SUPPLY CABLE

F10T-63ET

30x60x29h

230V~3 50/60 Hz

7,15

17,95

4 x 2,5 mm²

F2/10T-66ET

60x60x29h

230V~3 50/60 Hz

14,3

35,9

4 x 6 mm²

 

Summary of Contents for F10T-63EM

Page 1: ...tructions ELECTRIC FRYERS FOR PROFESSIONAL USE F10T 63EM F10T 63ET F2 10T 66EM F2 10T 66ET F13 64ET Model LIBR ISTR F60ENEW POT Code 563012503 Review 1 Edition date 12 09 2019 Language English LOTUS S...

Page 2: ...onic equipment 9 2 3 Technical data table 9 3 INSTALLATION 11 3 1 Delivery checks 11 3 2 Removing the packaging 11 3 3 Mechanical installation 11 3 4 Electrical gas connections 11 4 INSTRUCTIONS FOR U...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F T A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 F A Data Plate C Electrical connection...

Page 5: ...INTRODUCTION Translation of the original instructions 5 1 2 Components FIG C ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Page 6: ...AM F10T 63ET F2 10T 66ET F13 64ET 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Resistor switching terminal block 6 Heating element 7 White indicator light 8...

Page 7: ...ons 7 WIRING DIAGRAM F10T 63ET F2 10T 66ET F13 64ET 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Heating element 6 White indicator light 7 Green indicator li...

Page 8: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 9: ...parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Eq...

Page 10: ...INFORMATION Translation of the original instructions 10 DESIGN ASSEMBLY TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS see technical data table POWER SUPPLY CONNECTION HEATING ELEMENT CONN...

Page 11: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 12: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 13: ...ny cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to...

Page 14: ...e that during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain...

Page 15: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 16: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...