Lotus F10T-63EM Installation And Operating Instructions Manual Download Page 12

INSTALLATION

Translation of the original instructions

12

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Note

 

The connection cable must have the following characteristics: it must be silicone type (to
withstand temperatures of 180 °C), and must have an appropriate cross-section for the power
of the appliance (see technical data table).

 

EQUIPOTENTIAL

 
The appliance must be connected to an equipotential system. The connecting screw is located on the rear of
the appliance and is marked by the yellow symbol above it.
 

Warning

 

The manufacturer is not liable for and does not indemnify damages caused by incorrect
inadequate installations that do not comply with these instructions.

Summary of Contents for F10T-63EM

Page 1: ...tructions ELECTRIC FRYERS FOR PROFESSIONAL USE F10T 63EM F10T 63ET F2 10T 66EM F2 10T 66ET F13 64ET Model LIBR ISTR F60ENEW POT Code 563012503 Review 1 Edition date 12 09 2019 Language English LOTUS S...

Page 2: ...onic equipment 9 2 3 Technical data table 9 3 INSTALLATION 11 3 1 Delivery checks 11 3 2 Removing the packaging 11 3 3 Mechanical installation 11 3 4 Electrical gas connections 11 4 INSTRUCTIONS FOR U...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F T A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 F A Data Plate C Electrical connection...

Page 5: ...INTRODUCTION Translation of the original instructions 5 1 2 Components FIG C ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Page 6: ...AM F10T 63ET F2 10T 66ET F13 64ET 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Resistor switching terminal block 6 Heating element 7 White indicator light 8...

Page 7: ...ons 7 WIRING DIAGRAM F10T 63ET F2 10T 66ET F13 64ET 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Heating element 6 White indicator light 7 Green indicator li...

Page 8: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 9: ...parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Eq...

Page 10: ...INFORMATION Translation of the original instructions 10 DESIGN ASSEMBLY TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS see technical data table POWER SUPPLY CONNECTION HEATING ELEMENT CONN...

Page 11: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 12: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 13: ...ny cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to...

Page 14: ...e that during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain...

Page 15: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 16: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...