![Lotus F10D-64ETX Installation And Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/lotus/f10d-64etx/f10d-64etx_installation-and-operating-instructions-manual_1941226016.webp)
INSTRUCTIONS FOR USE
Translation of the original instructions
16
If using the fryer with products other than oil (lard, for example) that have considerable
thermal inertia, it is necessary to set the thermostat to a low value (e.g. 110°C) during the first
cycle (not starting cold). The thermostat can be set to the maximum only after the entire mass
has melted
4.4
Emptying the tank
The user is required to have a suitable recipient for emptying the oil. This recipient must be made of
heat-resistant material and must ensure that, during the emptying stage, the oil does not overflow and does
not represent a hazard. We recommend filtering the oil every day at the end of work and changing it when
necessary. Turn the oil drain cock into the horizontal position. Take special care if the oil is hot.
Note
Pay close attention to the distance between the appliance and the edges of the basin.