Lotus F10D-64ETX Installation And Operating Instructions Manual Download Page 13

INSTALLATION

Translation of the original instructions

13

Note

 

The ID plate is located in the compartment inside the door for appliances with compartments, or on
the left side for appliances with an oven or a top. A second plate with the model and serial number is
located inside the dashboard and a third is included with the certificate of conformity. The serial
number can also be tracked from the sales document (after 2008). The plate has all the data needed
for correct electrical installation. The installation and possible conversion to another power supply
voltage (if envisaged) must be implemented exclusively by professionally qualified and authorized
personnel. Before using the appliance, carefully clean all surfaces intended to come into contact with
food.

 

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Summary of Contents for F10D-64ETX

Page 1: ...g instructions ELECTRIC FRYERS FOR PROFESSIONAL USE F10D 64ETX F2 10D 66ETX F18D 64ETX F2 8D 64ETX Model LIBR ISTR FDX POT Code 563022401 Review 1 Edition date 22 04 2020 Language English LOTUS S p A...

Page 2: ...ctrical and electronic equipment 11 2 3 Technical data table 11 3 INSTALLATION 12 3 1 Delivery checks 12 3 2 Removing the packaging 12 3 3 Mechanical installation 12 3 4 Electrical gas connections 12...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F10D 64ET F2 10D 66ET...

Page 4: ...INTRODUCTION Translation of the original instructions 4 MODEL A B C F10D 64ETX 400mm 200mm 87 5mm F2 10D 66ETX 600mm 150mm 37 5mm B Electrical connection...

Page 5: ...INTRODUCTION Translation of the original instructions 5 FIG 2 F18D 64ET B Electrical connection...

Page 6: ...INTRODUCTION Translation of the original instructions 6 FIG 3 F2 8D 64ET B Electrical connection...

Page 7: ...ol knob to zero but the system remains operational until the problem that caused the intervention is resolved Contacts 80 and 81 are provided to enable the fryer to be controlled from a remote locatio...

Page 8: ...tions 8 WIRING DIAGRAM C 1 Cicada 2 Switch 3 Microswitch 4 Power supply terminal board 5 Heating element 6 Resistance voltage drop 7 White indicator light 8 Red indicator light 9 Green indicator light...

Page 9: ...INTRODUCTION Translation of the original instructions 9 Electrical technical data table MODEL WIRING DIAGRAMS F10D 64ETX C F18D 64ETX C F2 10D 66ETX C C F2 8D 64ETX C C PREDISPOSITION 440V 3...

Page 10: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be he...

Page 11: ...nt and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the...

Page 12: ...nding the heat emitted by this appliance Connect the water supply if necessary Caution Do not install the appliance near equipment machines used in cold processes If the appliance has to be installed...

Page 13: ...in our production range A minimum distance of 10 cm between appliances must be respected to prevent contact with any walls made of flammable material furthermore appropriate measures should also be a...

Page 14: ...cross section for the power of the appliance see technical data table EQUIPOTENTIAL The appliance must be connected to an equipotential system The connecting screw is located on the rear of the appli...

Page 15: ...leaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the...

Page 16: ...ass has melted 4 4 Emptying the tank The user is required to have a suitable recipient for emptying the oil This recipient must be made of heat resistant material and must ensure that during the empty...

Page 17: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 18: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Page 19: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: