INSTRUCTIONS FOR USE
Translation of the original instructions
18
Caution
If the probe does not detect water in the tank for more than 15 sec., the system disables the
heating element: an alarm is signalled by the red indicator light flashing. When the probe
detect water again, the heating element is activated and the red indicator light switches OFF.
·
TIME-OUT
Once the level probe is uncovered, the micro-controller activates an internal timer for the duration of this
stage. If the filling lasts (continuously) for more than 350 seconds, the system blocks the operation of the
device and an alarm is signalled by the red indicator light ON steady. To reset the alarm condition, first
eliminate the fault that caused it to trip (broken or disconnected level probes, water system problems, drain
tap open ...) and then switch the system OFF/ON .
4.7
Characteristics of the feed water
The inlet must be supplied with drinkable water having the specific characteristics listed below, otherwise
the warranty will be forfeited
·
Total hardness between 0.5 and 5 French degrees to reduce the formation of scale
·
Pressure between 50 and 250 kPa (0.5-2.5 bar)
·
pH above 7
·
Electrical conductivity between 50 and 2000 μS/cm (20 °C)
·
Chloride ion concentration (Cl-) not too high (acceptable reference value: 10ppm) to avoid attacking
the internal steel structures