- 8 -
OPERATION INSTRUCTION
TIG WELDING DESCRIPTION
1. Turn on the power switch at the front panel, digital current meter is normal, fan begins to rotate.
2. Open the valve of argon cylinder , adjust the volume of flow meter and make it is adequate to
welding .
3. Press switch of torch, electromagnetic valve is started. Sound of HF arc striking can be heard,
at the same time argon is flowing from torch burner. NOTES: When welding is first operated,
user must press switch of torch several seconds and begin to weld until all of air is be drained
out. When welding is over, argon will still flow out in several seconds in order to protect
welding spot before cooled down .So torch must be kept welding place some time before arc
has been extinguished.
4.
Set suitable welding current and make sure welding current is adequate to thickness of
workpiece and process demand.
STICKING DESCRIPTION
1
)
It is 2-4 mm from welding tungsten electrode to workpiece, press control knob of torch, burn
and strike arc, sound of HF arc-striking will be diminished. The welding machine can be
operated now.
2
)
Open power switch of front panel, fan is beginning to work.
3
)
Make sure function switch of front panel is on “down” position that is sticking. Impulse
changeover switch and knob of current down-slope time will not work.
4
)
Make sure welding current is adequate to thickness of work piece.
warning
:
During welding, it is forbidden to pull off any plug or cable in use,
or it will lead to life-threatening danger and sever damage of the machine.