16
/
21
OUTPUT CONNECTION
(Figure A.3)
The plasma cutting torch and ground cable are supplied with the plasma cutter. To connect the
cables, turn the Power Switch “OFF”.
1.
Plug the major power connector (the wider wire)
from the torch cable to the “Cutting Torch” output
terminal (5)
3
. Turn it clockwise using the plastic safe
protector until snug, do not over tighten.
2.
Plug the 2-prong connector from the torch cable into
the 2-pin socket marked as “Switch” (7). Turn the
outer metal shell clockwise to tighten.
3.
Connect the ground cable & clamp to the “Earth
Clamp” output terminal (6) and turn it clockwise to
tighten.
To minimize high frequency interference, refer to
Machine Grounding and High Frequency Interference
Protection section of this manual for the proper
procedure on grounding the work clamp and work piece.
To avoid receiving a high frequency shock, keep the plasma cutting torch and
ground clamp & cable Insulation in good condition.
3
The number inside “( )” is the annotation in section
Specifications
– Controls and Setting.