Lorentz PS150C Instructions For Installation, Operation And Service Download Page 8

v110801

8

Sun. Water. 

Life.

BERNT LORENTZ GmbH & Co. KG 

Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, 

www.lorentz.de

 

Errors excepted and possible alterations without prior notice.

Date of installation

Installer 
(full contact details)

Well depth 

m | ft

Pump depth 

m | ft

Additional vertical lift (to top of tank) 

m | ft

Static water level 

m | ft

Drawdown level 

m | ft

Drop pipe (vertical from the pump)

 

Size 

mm

2

 | in

 

Type

 

Length 

m | ft

Additional pipe length (to tank) 

 

Size 

mm

2

 | in

 

Type

 

Length 

m | ft

Submersible pump cable

 

Wire size 

mm

2

 | AWG

 

Length (controller to pump) 

m | ft

 

Max. RPM control 

 

Factory setting is maximum. 

yes 

no

If this setting was reduced, 
enter setting here:

Date of purchase

Dealer 
(full contact details)

System voltage 

V

Battery system 

yes 

no

Quantity of solar modules

Solar module brand 

Module model #

Controller model 

PS150

Controller serial #

Pump end model #

Pump end serial #

Motor model #

Motor serial #

7 System Report

System und Components

Installation

Summary of Contents for PS150C

Page 1: ...g the same Controller PS150 The solar battery is charged up during daylight hours using a separate charger The charger works effectively during re duced sunlight conditions when direct pump operation...

Page 2: ...pump owner Please give this ma nual to the pump owner or maintenance personnel when the installation is fini shed 2 Warnings The manual contains basic instructions which must be observed during mounti...

Page 3: ...gevity and enclosed for cleanliness and safety Connect the battery 12V or 24V directly with the and terminal of the controller Do not use the load terminals of the charge controller as they maybe not...

Page 4: ...s However the backwards pumping flow will be considerably less and the lift ability lower Make sure that the pump turns counter clockwise as indicated on the pump and motor body If you place it in a w...

Page 5: ...bility Secure the wires to tracker with plenty of tape Leave a good slack loop to allow free motion of tracker 4 2 24V Battery System 24V system Wiring scheme shows serial wiring for a sys tem of 24V...

Page 6: ...r Setting for PS150C Mode Before start up check that jumper Jmp2 is set to PS150C mode cf sketch on the right 4 5 High run Mode In order to set the battery high run mode set the jumper Jmp1 as shown i...

Page 7: ...em or 24V 24V system If the pump was recently connected or reconnected 2 to the controller it may be running in reverse direction due to wiring error See section 4 7 If the motor shaft only vibrates a...

Page 8: ...p pipe vertical from the pump Size mm2 in Type Length m ft Additional pipe length to tank Size mm2 in Type Length m ft Submersible pump cable Wire size mm2 AWG Length controller to pump m ft Max RPM c...

Reviews: