6 Wiring and Operation
6 Wiring
Connect the PV modules to PV IN then
connect DC out of the PowerPack to
the controller, paying attention to the
polarity. Check the voltage from the PV
generator. The voltage must not exceed
the open circuit values listed in “Table 3”
below.
Table 3:
Max. PV input voltage
PP600S
PS200
100 V DC
PS2-200
100 V DC
PS2-600
150 V DC
Select the wire that will fit to your grid
connection socket and connect it to the
PowerPack. Before connecting to grid,
ensure that the grid connection is prop-
erly protected with a fuse and if required
with an ELCB, all according the national
electrical guidelines.
7 Operation
Connect the AC power source and switch
on the PowerPack AFTER it has been
connected to the pump controller. When
the controller and the PowerPack are
switched on, the system ON light should
flash on the controller and the pump
should start.
WARNING – Beware of high volt-
age! Hazardous electricity may
be present and can shock, burn
or cause death! Authorized,
qualified personnel only!
CAUTION – The PowerPack
should only be connected to
power after correct wiring or
the controller might get dam-
aged.
CAUTION – Do not connect any
electrical load to the PV gener-
ator other than the LORENTZ
pump controller and Power-
Pack. Connection of battery
charger, active solar tracker
controller, electric fence charg-
er or other load simultaneously
with LORENTZ PS2 systems may
interfere with the controller
and prevent proper operation.
CAUTION – Measure the voltage
before connecting power to the
Powerpack. Follow the guide-
lines included in this manual
regarding maximum PV input
voltages.
CAUTION – Do not connect the
PV modules to the DC output as
it may damage the PV modules.