The THL105 is a compact field mount thermostat for regulating heating cables and ribbons, allowing control of resistive 
load up to 3.5 kilowatts. The digital regulation allows to combine precision and ease of use.  
Temperature and setpoint are displayed on a large LCD display. 
 
 
 
Technical specifications can be downloaded at:  

http://www.loreme.fr/fichtech/THL105_eng.pdf

 

 

 

 

 

 

 

 

       

 
 

USER INTERFACE 

 
 
 
 
 
 
 
 
 
 

 
 
 

 

 
 
 
 
 
 
 
 
 

 
 
 

 

Visualization 

 

 
160°C  out: off  

Temperature and output relay state.

 

SET point:140°C  

Setpoint. 

 
 
The push buttons allow a direct adjustment of the setpoint. The 

 button allows you to increment the setpoint and the 

 

button to decrement it. The setpoint is incremented or decremented in steps of 1 °C at the beginning. Holding pressed 
the 

 or 

 button for more than 4 s will increment or decrement the setpoint in 10 °C steps. 

 
 

Configuration 

 
An advanced configuration is accessible via the 'Config' button. The user can thus configure the hysteresis and delay 
parameters of the regulation. 
 
The regulation works as follows: 
- The load is energized when the temperature drops below the setpoint and after the configured delay time. 
- The load is no longer supplied when the temperature goes above the threshold plus the hysteresis. 

 
Device Presentation 

Buttons 

Terminals for PT100

 

LCD display 

2 lines / 16 characters

 

Summary of Contents for THL105

Page 1: ...S AND RIBBONS LOREME 12 rue des Potiers d Etain Actipole BORNY B P 35014 57071 METZ CEDEX 3 Phone 03 87 76 32 51 Contact Commercial Loreme fr Technique Loreme fr Download manual at www loreme fr CONFI...

Page 2: ...RATION p3 1 Hysteresis configuration p4 2 Delay configuration p4 3 End of configuration p4 RS232 LINK SETTING p5 TERMINAL MODE p6 Visualization p6 Configuration p6 1 Method p6 2 Configurable parameter...

Page 3: ...etpoint The button allows you to increment the setpoint and the button to decrement it The setpoint is incremented or decremented in steps of 1 C at the beginning Holding pressed the or button for mor...

Page 4: ...e Config button to validate the setting 0 to 50 C 2 Delay configuration RETARD Press the or button to increment or decrement the delay value 0 1 s steps 0s Press the Config button to validate the sett...

Page 5: ...ates another communication port number COMx and re quires the reconfiguration of the HyperTerminal The terminal emulation software for PC HyperTerminal is resident in windows up to XP version For late...

Page 6: ...modification by typing Enter The modification with simultaneous display followed by validation with Enter key 2 Configurable parameters The following parameters can be configured The threshold setpoin...

Page 7: ...s 100 5 C Temperature value with offset OFFSET 0 5 offset function temperature offset value Use keys and to adjust offset the temperature is directly modified Type on Enter to save the new offset OFFS...