8
Pc-boards
Pc-board DP-MAPRO
The pc-board DP-MAPRO is responsible for the welding sequence and is managing the process control of the
S-Series.
(MAPRO =
MA
ster-
PRO
cess)
Functions
- Logicfunctions of the welding process
- generating and monitoring supply voltages
- driving powerup-relais
- driving power unit/units
- monitoring control and operating elements (DS20BF, remote control, torch buttons)
- driving fans
- driving coolingpump
- monitoring flowmeter
- monitoring mains- and output voltage
- generating signal „welding current on“
- managing communications between PC and machine
- managing and storage of all welding parameters
- CAN-bus
LED displays :
If the LEDs are indicating a malfunction which can not be relieved by switching the machine off and on again,
it is recommended that the pc-board DP-MAPRO is exchanged.
normal
LED
state
designation
1 (green)
flashing (half freq. of LED5)
CPLD-processor ok
2 (red)
off
D
igital
S
ignal
P
rocessor (DSP) ok
3 (green)
on
supply voltage 3,3V DC ok
4 (red)
off
micro controller ok
5 (green)
flashing
DSP is working
6 (green)
flashing
micro controller is working
malfunction
LED
state
designation
1 (green)
never on
CPLD-processor is not working
2 (red)
on
DSP is not working
3 (green)
off
supply voltage 3,3V DC is missing
check 18V~ AC of control transformer X2/1 X2/2
4 (red)
on
micro controller is not working
5 (green)
never on
DSP is not working
6 (green)
never on
micro controller is not working