Lopi Northfield Owner'S Manual Download Page 30

30

   Finalizing the Installation

 (for qualified installers only)

 

© Travis Industries 

4091120 

100-01239_000 

Glass Frame Removal and Installation (continued) 

The latch can come loose from glass frame anchor.  This occurs when it is turned 1/4 
turn when it is disengaged.  Follow the directions below to re-install the latch if it 
becomes loose. 

Top of 
Firebox

Hold the latch at an angle and insert it into the slot on the glass frame anchor.

NOTE:  this slot may be at a 
different angle than illustrated.

 Note how the washer on the latch fits behind the flange on the 
glass frame anchor.

Glass Frame 
Anchor

Once fully inserted, turn the latch until it is upright.

Latch

 

Summary of Contents for Northfield

Page 1: ...not use any phone in your building Immediately call gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installat...

Page 2: ...er Northfield Stove has the same serial number as yours The serial number is on the listing plate chained to the gas control valve This serial number will be needed in case you require service of any...

Page 3: ...estrictor Extender Plate 17 Diffuser 17 Vent Termination Requirements 24 Class A Chimney Conversion 25 Interior Masonry Chimney Conversion 26 Finalizing the Installation Leak Test 27 Pilot Adjustment...

Page 4: ...ety hazard Direct questions about the type of fuel used to your dealer Check for a label on the flame adjust knob on the gas control valve this is the best place to check You may also check for a labe...

Page 5: ...urn the gas off at the gas control valve and call your dealer for service Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve The gas main shutoff val...

Page 6: ...h Blower 500 to 650 Without Maximum Input in BTU s 22 000 Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temperature Dimensions Weight NOTE Measure...

Page 7: ...sing only after the home is site located This stove is designed to operate on natural gas or propane LP All exhaust gases must be vented outside the structure of the living area Combustion air is draw...

Page 8: ...Paint Batteries 4 AA and 1 9v Rear Vent Flue Cover Intake Damper Plates 2 Exhaust Restrictor Extender Plate Additional Items Required Vent see Venting Requirements for details Gas Line Equipment shut...

Page 9: ...rt this heater This is normal We recommend you open windows to vent the room Stove Clearances NOTE If using the rear vent configuration you will require approximately 8 1 2 to the rear of the stove fo...

Page 10: ...gnetic tipped nutdriver on these screws take care to prevent the screws from falling into the intake channel Remove the diffuser Before Stock Position 1 After Position 2 DIFFUSER SIDE VIEW Bend the ro...

Page 11: ...er plate Make sure the attached gaskets are in place and form an air tight seal NOTE Install the flue assembly with the diffuser to the bottom Install the outer flue assembly cover plate and gaskets M...

Page 12: ...placed so the vents below or above the door along the sides of heater or along the back of the heater can become blocked This heater may be placed in a bedroom Please be aware of the large amount of...

Page 13: ...upt the burner circuit see item a below 1 If you wish to bypass the switch connect the thermostat on off switch wires directly to the green and white wires see b below 2 If you wish keep the switch se...

Page 14: ...ation of the gas inlet is shown below A manual shutoff valve is required for installation it must be located within 3 of the heater T Handle gas cocks are required in Massachusetts in compliance with...

Page 15: ...proved for this stove Use a firestop whenever passing through a ceiling Vertical Termination NOTE always use the high wind version if applicable Use a roof flashing and storm collar whenever passing t...

Page 16: ...the charts under Approved Vent Configurations Remove the screw Rotate the adjustment plate counter clockwise until the correct index hole is over the screw hole Insert the screw into the correct inde...

Page 17: ...efer to the vent configuration pages 18 to 23 to determine if the extender must be installed Exhaust Restrictor Extender Plate found in the owner s pack Remove these two screws on the exhaust restrict...

Page 18: ...2 pieces Thimble Cover Black Pipe Section 3 9 High Wind Horizontal Cap Place the 6 5 8 to 8 adapter directly onto stove see illustration below Maximum Horizontal Run of 4 Horizontal sections require a...

Page 19: ...ghtly especially when the termination is near a demarcation line Diffuser set to open stock position Do not install the intake damper plate or exhaust restrictor extender plates 5 feet 1 5m 10 feet 3m...

Page 20: ...s NOTE Restrictor positions are based upon lab tests The ideal restrictor position may vary slightly especially when the termination is near a demarcation line Diffuser set to open stock position Inst...

Page 21: ...ces to combustibles must be met and the flex vent must be vented through a non combustible fireplace chimney Use a high wind termination cap Vent height must be a minimum 10 and maximum 25 Diffuser mu...

Page 22: ...tion line Diffuser set to open stock position Install the intake damper plate Install the exhaust restrictor extender plate 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 40 ma...

Page 23: ...mination is near a demarcation line Diffuser set to open stock position Do not install the intake damper plate or exhaust restrictor extender plates 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 5 fe...

Page 24: ...in accordance with local installation codes and the requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above any grade when adjace...

Page 25: ...Kit A 931 Metalbestos 6 I D Security Chimneys 6 I D Jackes Evans 6 I D Hart Cooley 6 I D Pro Jet 6 I D Chimney Conversion Kit B 932 Simpson Dura Vent 6 I D Air Jet 6 I D Metal Fab 6 and 7 I D Amer Met...

Page 26: ...spect the chimney 711 Flex Liner 4 dia or other UL 1777 Gas Liner Co Axial Straight Lengths 991 High Wind Termination 990 90 Elbow Flashing included in 934 Masonry Conversion Kit Make sure the coaxial...

Page 27: ...ure the accent light bulb is in place NOTE Take care to not touch the bulb with your fingers use a cloth or paper towel 4 Install the four AA batteries included in the owner s pack into battery holder...

Page 28: ...the top If the flames are too tall or sooty on the ends open the air shutter Not Enough Air If the flames are all blue and short close the air shutter Too Much Air Swing the control cover down to acc...

Page 29: ...des hold the glass frame at a slight angle b Swing the glass frame into place you may have to lift it slightly to allow it to fit over the top of the firebox c Attach the upper latches follow the inst...

Page 30: ...ed 1 4 turn when it is disengaged Follow the directions below to re install the latch if it becomes loose Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame ancho...

Page 31: ...or failure to use only parts specifically approved with this appliance may result in property damage or personal injury If using propane LP convert the appliance before installing the logs see page 4...

Page 32: ...ne hole and one elevated pad on the bottom Place the log so the pin on the burner inserts into the holes on the log and the pad inserts over the screw on the burner see photos below Right Log Placemen...

Page 33: ...to below The bottom of the twig has two holes Place the twig so the pins on the rear and left log insert into the holes on the twig Right Twig Placement The right twig has two holes in the bottom that...

Page 34: ...l is placed on top of the burner to enhance the glow from the burner The rock wool works best when it is applied in a very thin porous layer The best method for applying the rock wool is to brush it o...

Page 35: ...RT PILOT COMFORT CONTROL AA BATTERY HOLDER 9 VOLT BATTERY HOLDER An instruction card for operating the fireplace is attached to the inside of the fireplace here Replace it for easy reference ON OFF Sw...

Page 36: ...main burner switch to turn the main burner on and off MAIN BURNER ON OFF NOTE FOR REMOTES THERMOSTATS OR WALL SWITCHES The on off switch on the stove may be required to be left in the ON or OFF positi...

Page 37: ...tions the homeowner may prefer to switch the stove to continuous pilot The most typical reasons for switching to continuous pilot are CONTINUOUS PILOT GREEN SMART PILOT Very Cold Conditions in very co...

Page 38: ...an optional blower to push heated air into the room You will hear the sound of air movement that increases as the speed is increased Extinction Pops It is not unusual especially on Propane LP applian...

Page 39: ...his is normal The only cleaning we recommend is a light dusting when the appliance is cool DO NOT USE ANY LIQUID CLEANER OR ABRASIVES ON THIS FINISH Glass Clean the glass with soap and water do not us...

Page 40: ...ce Check the logs for sooting A small amount of soot along the bottom of the logs is normal If excessive sooting is found the stove will require adjustment Contact your dealer 4 Inspect the burner and...

Page 41: ...is set too low Turn the ON OFF switch to ON Check thermostat Stove Will Not Distribute Heat The stove is not getting electricity The stove is not up to temperature Check the breaker switch Let the st...

Page 42: ...LOT AC ADAPTER Red Red Black White Green Black Red Red Blue Red Blue Black White Blue Yellow Green Orange Pilot Sensor Spark Rod Pilot Ground VALVE IPI CPI POWER SUPPLY ON OFF Green 120 VAC Power In O...

Page 43: ...ting system in accordance with the manufacturer s installation instructions Use only approved coaxial direct vent system to vent this appliance to the exterior See owner s manual for approved brands o...

Page 44: ...ustment of the manufacturer s settings of components lack of proper and regular maintenance damage incurred while the appliance is in transit alteration or act of God 8 This 7 Year warranty excludes d...

Page 45: ...onversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use 1 Remove the glass see page 29 Remove the logs and embers if installed page 31 2 Remove the...

Page 46: ...so the orifice protrudes 15 16 24mm indicating full insertion c Look here for the orifice identification Apply thread sealant to the LP orifices prior to installation Use the chart below to identify...

Page 47: ...glass 6 Remove and discard the screws see a below holding the stock regulator in place see b below Remove the stock regulator and gasket see c below Place the LP regulator in place making sure the pr...

Page 48: ...smitter Receiver with Cover Plate Switch Fan Control Module Velcro LP or NG Stepper Motor with screws and label attaches to Valve Wire Harness 2 Power Leads 4 AA Batteries inside receiver box 2 8 x Ma...

Page 49: ...d and following page Stock Wiring Diagram CN4 CN3 PILOT SENSOR SPARK ROD DIGITAL FIREPLACE BURNER CONTROL CN2 GROUND VALVE COMMAND POWER CN1 DIAGNOSTIC CN0 COMFORT CONTROL AA BATTERY TRAY MAIN BURNER...

Page 50: ...LVE COMMAND POWER CN1 DIAGNOSTIC CN0 CONTINUOUS PILOT White Blue Yellow Green Orange VALVE IPI CPI TOP 4 AA Batteries Remote Receiver Fan Controller 110V OUT FAN AUX OUT COM POWER STEPPER MOTOR BURNER...

Page 51: ...there are two on each side see Figure 1 Slide the bottom panel back and place it below the stove see Figure 2 This allows for access to the controls under the stove NOTE The fireplace controller is s...

Page 52: ...the wiring harness Figure 5 4 Disconnect the molex connector leading to the gas control valve see Figure 6 WARNING The tabs on the gas control valve are fragile Take care when removing the molex conn...

Page 53: ...rner control see Figure 9 Figure 8 Figure 9 7 Disconnect the on off switch wires labeled ON OFF see Figure 10 Unscrew the on off battery plate from the control panel see Figure 11 Figure 10 Figure 11...

Page 54: ...lation sheet included with it make sure to follow all of the directions Place the stepper motor on the gas control valve see Figure 15 MAKE SURE IT IS CORRECTLY ORIENTED Secure using the screws includ...

Page 55: ...l see Figure 18 Attach the gas control valve molex connector see Figure 19 Figure 18 Figure 19 13 Attach the blue and white wires to the IPI CPI switch see Figure 20 Connect the wiring harness to the...

Page 56: ...bottom panel Figure 23 16 Attach the power cord from the fan controller to the AC connection see Figure 24 Attach the connector labeled FAN CONTROL on the wiring harness to the fan control module see...

Page 57: ...will want to disconnect its power lead and connect it to the extra power lead included with this kit then connect it to the FAN receptacle on the fan controller See the blower installation instructio...

Page 58: ...being pinched see Figure 32 Use the included wire ties if necessary to keep all wiring from contacting any hot or moving components Figure 32 22 Place batteries into the receiver and transmitter see...

Page 59: ...two screws included with the receiver see Figure 36 Figure 35 Figure 36 24 A wall mount is included with this kit for the remote It may be mounted to the wall for easy access and storage Use the inclu...

Page 60: ...29 Hearth Requirements 12 Heating Specifications 6 Horizontal Vent Termination Requirements 24 Installation Options 6 Items Required for Installation 7 Leaking Gas See Inst on Cover Listing Informati...

Reviews: