background image

TO MEASURE  

BREAKING STRENGTH:

When a loop or splice is properly swaged, 

Locoloc

®

 copper and aluminum oval sleeves 

are capable of supporting a greater load than 

the rated breaking strength of the flexable 

construction metal cable to which they are 

attached. Locoloc® stop sleeves are capable 

of holding only 1/3 to 1/2 of the rated breaking 

strength of the cable.ratedratebreaking 

strength of the cable to which they are 

attached. 

CAUTION:

Always use a five to one safety factor 

when designing cable assemblies.

If the strength of the cable is 2,000 lbs. 

(1/8" 7X19 galvanized aircraft cable) then 

the maximum load to which the cable 

or the assembly is subject should never 

exceed 400 lbs. When an oval sleeve or 

other fitting capable of holding the rated 

breaking strength of the cable is used as a 

termination.  When a stop sleeve is used this 

safety factor should be increased to 10 to 1.

TABLE A      

Suggested starting gauge pressure

Sleeve size 

Description 

 

 

Pressure*(Gauge) 

Dies 

 

3/64 

 

Copper oval and stop sleeves 

   200 lbs. 

 

3/64 Dies

1/16 

 

Copper oval and stop sleeves 

   250 lbs. 

 

1/16 Dies

3/32 

 

Aluminum oval and stop sleeves 

   300 lbs. 

 

3/32 Dies

3/32 

 

Copper oval and stop sleeves 

   450 lbs. 

 

3/32 Dies

1/8 

 

Aluminum oval and stop sleeves 

2,000 lbs. 

 

  1/8 Dies

1/8 

 

Copper oval and stop sleeves 

2,500 lbs. 

 

  1/8 Dies

5/32 

 

Aluminum oval sleeves 

 

2,700 lbs. 

 

5/32 Dies

5/32 

 

Aluminum stop sleeves 

 

2,700 lbs. 

 

 1/8 Dies

5/32 

 

Copper oval sleeves 

 

3,000 lbs. 

 

5/32 Dies

5/32 

 

Copper stop sleeves 

 

3,000 lbs. 

 

  1/8 Dies

3/16 

 

Aluminum oval sleeves 

 

4,000 lbs. 

 

3/16 Dies

3/16 

 

Aluminum stop sleeves 

 

4,000 lbs. 

 

  1/8 Dies

3/16 

 

Copper oval sleeves 

 

4,500 lbs. 

 

3/16 Dies

3/16 

 

Copper stop sleeves 

 

4,500 lbs. 

 

  1/8 Dies

7/32 

 

Aluminum oval sleeves 

 

5,000 lbs. 

 

7/32 Dies

7/32 

 

Aluminum stop sleeves 

 

5,000 lbs. 

 

  1/8 Dies

7/32 

 

Copper oval sleeves 

 

5,000 lbs. 

 

7/32 Dies

7/32 

 

Copper stop sleeves 

 

5,000 lbs. 

 

  1/8 Dies

1/4 

 

Aluminum oval and stop sleeves 

5,000 lbs. 

 

  1/4 Dies

1/4 

 

Copper oval and stop sleeves 

5,500 lbs. 

 

  1/4 Dies

9/32 

 

Aluminum oval sleeve 

 

5,500 lbs. 

 

9/32 Dies

9/32 

 

Copper oval sleeves 

 

5,500 lbs. 

 

9/32 Dies

9/32 

 

Copper oval stop sleeves   

5,500 lbs. 

 

  1/4 Dies

5/16 

 

Aluminum oval sleeve 

 

5,500 lbs. 

 

5/16 Dies

5/16 

 

Copper oval sleeves 

 

5,800 lbs. 

 

5/16 Dies

5/16 

 

Copper stop sleeves 

 

5,800 lbs. 

 

  1/4 Dies

3/8 

 

Aluminum oval sleeve 

 

6,000 lbs. 

 

  3/8 Dies

3/8 

 

Copper oval sleeves 

 

6,500 lbs. 

 

  3/8 Dies

3/8 

 

Copper stop sleeves 

 

6,500 lbs. 

 

  1/4 Dies

7/16 

 

Aluminum oval sleeve 

 

6,500 lbs. 

 

7/16 Dies

7/16 

 

Copper oval sleeve 

 

6,500 lbs. 

 

7/16 Dies

1/2 

 

Aluminum oval sleeve 

 

6,500 lbs. 

 

  1/2 Dies

1/2 

 

Copper oval sleeve 

 

6,500 lbs. 

 

  1/2 Dies

 

* 5/16, 7/16, 1/2 and 3/8” sleeves require two compressions. 

Each compression will swage 1/2 the length of the sleeve.

www.loosnaples.com

Toll Free: 800-321-LOOS (5667)

4

Summary of Contents for LOCOLOC 5-H

Page 1: ... 5 H HYDRAULIC SWAGER Locoloc Swaging Tools ...

Page 2: ...DIE SET Remove four screws on right side of the upper and lower dies then slide the dies out To install place new dies in die shoe lining up screw holes with die shoe DO NOT OPERATE MACHINE WITH DIES REMOVED FROM DIE SHOE This will damage the die shoe and may be hazardous to your safety FIGURE 3 To re adjust die set opening for swaging different cable sizes 1 Turn the pump unit on 2 Loosen the 3 8...

Page 3: ... approx 2 inches below the frame To add hydraulic oil remove cap Figure 6 and fill hydraulic oil Use only Enerpac HF 101 hydraulic oil part 4 54HS FIGURE 6 BEFORE OPERATING 1 Re check hydraulic hoses to ensure they are connected to the correct ports and tightened all the way 2 Make sure the ram return micro switch is set correctly When the die set is open and the ram is in the returned position th...

Page 4: ...hich if ignored can be dangerous All fittings hoses gauges etc must be proven for 10 000 PSI 60 000 PSF operation Use only Enerpac hydraulic oil Most hydraulic oils are designed for low PSI systems TO SET PRESSURE Always make sure the die set is in the die shoe before turning the unit on 1 Plug the machine into a 120 volt 60Hz outlet The LCD display backlight will be on and in the auto mode Ram is...

Page 5: ...r oval and stop sleeves 2 500 lbs 1 8 Dies 5 32 Aluminum oval sleeves 2 700 lbs 5 32 Dies 5 32 Aluminum stop sleeves 2 700 lbs 1 8 Dies 5 32 Copper oval sleeves 3 000 lbs 5 32 Dies 5 32 Copper stop sleeves 3 000 lbs 1 8 Dies 3 16 Aluminum oval sleeves 4 000 lbs 3 16 Dies 3 16 Aluminum stop sleeves 4 000 lbs 1 8 Dies 3 16 Copper oval sleeves 4 500 lbs 3 16 Dies 3 16 Copper stop sleeves 4 500 lbs 1 ...

Page 6: ...www loosnaples com Toll Free 800 321 LOOS 5667 5 Pressure Gauge Foot Switch Pump Unit ...

Page 7: ...www loosnaples com Toll Free 800 321 LOOS 5667 6 ...

Page 8: ...104 USA Telephone 239 643 LOOS 5667 1 800 321 LOOS 5667 Fax 239 643 4558 E Mail info loosnaples com Website www loosnaples com Specialists in Wire Rope Hardware Tools Rev 9 19 2018 INST 32 HOW TO VIDEO https www youtube com watch v 0n0HDZ6yWNc ...