4. Fluid
The location for the
Tiny S
must
• be dry
• guarantee sufficient air supply
• be at least 60 cm from inflammable materials
• have very little vibration
• have an ambient operating temperature between 5° C and 45° C
• have a relative air humidity of less than 80%.
5.1 Selecting the Location
5.2 Mounting the Tiny S
If the
Tiny S
is be built into props or similar, make sure that a fog-free air supply is
guaranteed. Too high a fog concentration can condense inside the machine and can
result in damages caused by moisture.
5. Operating the Tiny S
The
Tiny S
is built to be used with original Look Tiny-Fluid. Use of other liquids will
clog the vaporizer and void the warranty.
4.1 General
The fluid reservoir can be refilled using the delivered refilling set [12]. Thus, the
reservoirs can be used several times.
a) Mount 5 ml of Tiny-Fluid from the original fluid bottle with the refilling set.
b) Connect the adaptor of the refilling set with the reservoir you would like to refill.
c) Disconnect the adaptor and screw the refilled reservoir into the
Tiny S
. If you refill
reservoirs for stock, please use the covers to avoid small bits of dirt inside the reservoir
and make sure the reservoir cannot leak.
4.2 Refilling the fluid reservoir