Operating manual

a

 

Look Solutions 

product

CRYO

GATE

Accessory for low fog 

to be used with CO

2

- high pressure tank

USA

Summary of Contents for Cryo-Gate

Page 1: ...1 Operating manual a Look Solutions product CRYO GATE Accessory for low fog to be used with CO2 high pressure tank USA...

Page 2: ...l version 2 2016 1 Cryo Gate 1 Connecting tube complete with connectors to connect the Cryo Gate to the CO2 tank 5 m 1 mains cable 2 m Powercon True plug 1 Inline Filter 1 Operating manual Please chec...

Page 3: ...on 10 4 4 1 Manual operation 12 4 4 2 Operting via analogue 13 4 4 3 Operating with DMX 14 4 4 4 Operating via Ethernet 15 4 4 4 1 Artnet 15 4 4 4 2 sACN 16 4 4 5 IP Configuration 17 4 4 6 More adjust...

Page 4: ...le has to be a W 21 8 x 1 1 4 right male CGA 320 connector If a tank with this connector cannot be found you have to use an adaptor A tube 200 mm can be connected to the front of the Cryo Gate to guid...

Page 5: ...ccasionally very hot droplets of fluid may escape when in operation Never aim at persons directly and keep a minimum distance of 3 m from the nozzle Never touch the nozzle when in operation Danger of...

Page 6: ...he method used here to produce fog with a device which works according to the vaporizer principle is the most harmless one No case has so far been reported in which a healthy human being has been harm...

Page 7: ...iquid CO2 tube 7 8 9 10 Connection to the high pressure CO2 tank with siphon tube 11 Avoid dust or dirt particles inside the CO2 hose Always ensure complete purity of all CO2 connectors and fittings 1...

Page 8: ...ct the CO2 tank to the Cryo Gate 10 using the supplied safety hose see page 7 Always ensure complete purity of all CO2 connectors and fittings If you should notice dirt particles connect the tube to t...

Page 9: ...ntrol via analogue If the machine will be controlled via analogue adjust the analogue remote in a way that the CO2 will be released Caution Due to the selected Presets the fog generator may start fogg...

Page 10: ...ments CO2 comes out at the end of the hose that has not been connected yet Close the valve properly and connect the other end of the hose to the Cryo Gate 10 Tighten both connections properly to make...

Page 11: ...already been used This value can be reset by pressing RESET for example if a new tank has been connected This value is only roughly measured and does not show the exact usage Third line Actual values...

Page 12: ...m high in 30 sec To choose a fixed preset Press PLUS or MINUS line 4 at the main screen Fig 1 until the requested preset appears Press START to start the fogging process The screen now changes to MANU...

Page 13: ...anges its colour to cyan You can return to the main screen pressing BACK 4 4 2 Operating via analogue Input voltage between 0 and 10 V If the voltage is higher than 1 V the machine will be controlled...

Page 14: ...ing into a different mode is actually not possible 4 4 3 Operating via DMX in Press the DMX Button at the main screen Fig 1 line 1 or press SETTINGS DMX The adjoining screen Fig 7 appears Here you can...

Page 15: ...DIFY button Fig 8 line 2 The screen shown on the right Fig 9 appears Corresponding to the standards for DMX and ARTNET a Universe consists of 512 DMX channels A Subnet contains 16 Universes and a Net...

Page 16: ...there are Universes between 1 and 63999 Press CE Fig 11 line 2 and type in the value for the selected Universe sACN UNIVERSE SAVE saves the value BACK switches back to the previous screen Fig 8 withou...

Page 17: ...d a subnet mask from a DHCP Server or Router in your network If you select STATIC you can type in the IP address and the subnet mask in the following screen Fig 13 Ask your network administrator if ne...

Page 18: ...main screen at the following Settings 1 screen NEXT and at the Settings 2 screen Fig 3 line 2 SCREENSAVER Press PLUS or MINUS to change the value Save the value with SAVE Press BACK to get to the prev...

Page 19: ...screen Fig 3 line 2 FACTORY RESET Press RESET only when you are sure that you would like to return to the factory settings Press BACK to get to the previous screen without starting the reset 4 4 6 4...

Page 20: ...e is been used with a tube there will be some residues in the tube and also the machine after a while Please disconnect the tube from the duct adaptor from time to time and wipe the inside with an abs...

Page 21: ...cifications Voltage 90 to 240 VAC Power requirement max 65 Watt Dimensions L x W X D 60 x 20 x 17 7 cm Weight 10 5 kg Manufactured for Look Solutions Fog machines made in Germany B nteweg 33 DE 30989...

Page 22: ...ty services if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are not approved by us The right of warranty service is also lost if liquid...

Page 23: ...23...

Page 24: ...24 a Look Solutions product...