11
5.4 Disconnect the machine from the tank
Important
:
Before you disconnect the tube, the CO
2
in the tube must ALWAYS be removed!
a. Close the liquid valve at the CO
2
-tank. Make sure that the valve is closed
properly.
b. Remove the CO
2
completely from the tube by doing the following:
At operation via DMX
:
The
Cryo-Fog
needs three channels on your desk (first channel = Pump, second
channel = Fan, third channel = Cooling).
Run the cooling channel (third channel) at full until no noise can be heard
from the machine – at a minimum for one minute.
Put the fader of your desk back into position “0“ and switch off the machine
or your desk.
At Stand alone mode or operating via analog XLR-remote
:
Press the Mode button [14] until “Co2“ appears at the display.
Press the Enter button [16] once. The fan starts to run automatically and three
seconds later the valve will open. The CO
2
is now expelled.
After all CO
2
is expelled, press the Mode-button again to close the valve.
Switch off the machine as described (point 5.3).
5. Operating the Cryo-Fog