5.3 Switching the device off

a. Press the Mode-button [14] til “OFF” appears on the display. After 15 seconds

the machines switches into the  post-run-mode automatically.
You can also switch the machine into the post-run-mode within these 15 seconds
by pressing the Enter-button [16].

The fan increases to the maximum output to dry the cooling chamber and
switch off automatically after three minutes. During this time lines appear on
the LED display [18] which move from the upper left edge down to the lower
right edge.

Then a little red point in the lower right edge of the display appears to show
that a voltage is present.

b. When you switch off the DMX signal, the machine will be switched into the

post-run-mode automatically after 15 seconds.

Note

:

Please make sure that the 

Cryo-Fog

 is not disconnected too early to allow the

fan to run until the cooling chamber is dry.

.

5. Operating the Cryo-Fog

_

  _   _

f. After a warm up time of approx. seven minutes the machine is ready to start.

The green Ready-Led [20] blinks when the working temperature is reached. As
soon as the final temperature is reached, the LED illumates permanently.

The machine is now ready to use. For adjustments please see chapter 5.5.

Summary of Contents for Cryo-Fog

Page 1: ...1 Operating manual Cryo Fog a Look Solutions product USA ...

Page 2: ...t supplied 1 Cryo Fog 1 Connecting tube complete with connectors to link the machine with the CO2 Tank 5 m 1 Tank lid with Quick Coupling 1 Operating manual Please check whether all the products you ordered are supplied ...

Page 3: ...cation 5 2 Putting into operation 5 3 Switching the device off 5 4 Disconnect the machine from the tank 5 5 Control choices 5 5 1 Control via DMX 512 5 5 1 1 Adjusting the DMX start address 5 5 1 2 Operation 5 5 2 Control via 0 10 Volt DC 5 5 3 Stand alone mode 5 6 Wiring of the connectors 6 Cleaning Care and Maintenance 16 7 Troubleshooting 17 8 Specifications 18 9 Warranty Conditions 19 ...

Page 4: ...id CO2 will be delayed in reaching the cooling chamber It will then take the cooling chamber longer to reach the correct temperature to produce low fog The Cryo Fog can be used as normal fog machine as well as a low fog machine When using it as a normal fog machine the Cryo Fog can be controlled via DMX512 only A stand alone control or control with analog remote is not possible The internal fog ma...

Page 5: ...burns with a slightly bluish almost invisible flame Never point the fog at strong sources of ignition like fire or pyrotechnic effects Never open the machine and leave the machine unattended when connected to a power supply The visibility must be more than 6 ft in rooms where people walk around Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water...

Page 6: ...ss coupling 10 Brass collar 11 Tank lid 12 Check valve 13 Fluid filter 10 12 Tank lid Front view 1 Fog nozzle 3 Descriptions of the parts Extrem temperatures hot cold C A U T I O N Do not touch vapour and nozzle area ...

Page 7: ...0 25 bar Read manual before use This machine has been designed to be used with original Look CRYO FOG fluid Use of other liquids will void the manufacturer s warranty and can be dangerous to your health Never use cleaner or fragrances with this machine Made by OTTEC Technology GmbH for Look Solutions Made in Germany 230 V 50Hz 2200W AFTER OPERATION 1 Close the valve at the CO2 tank 2 Exhaust the C...

Page 8: ... NOTE The vaporizer of our machines does not have to be cleaned Cleaners available on the market can damage the vaporizer Use of cleaners will invalidate waranty PLEASE NOTE After using the Cryo Fog as a normal fog machine all Quick or Regular fog must be removed from the fluid tube 4 2 Changing the fluid container Disconnect the fluid tube from the lid by retracting the brass collar 10 and removi...

Page 9: ...ating temperature between 40 F and 115 F and the relative air humidity below 80 a Connect the delivered safety tube for liquid CO2 with the liquid valve at the tank Make sure that the tank is a low pressure tank 20 24 bar 200 250 psi Do not to use tanks or bottles with higher pressure with this machine Tighten the connection to make sure that no gas can escape b Open the liquid valve to flush fitt...

Page 10: ...e lower right edge Then a little red point in the lower right edge of the display appears to show that a voltage is present b When you switch off the DMX signal the machine will be switched into the post run mode automatically after 15 seconds Note Please make sure that the Cryo Fog is not disconnected too early to allow the fan to run until the cooling chamber is dry 5 Operating the Cryo Fog _ _ ...

Page 11: ...ling Run the cooling channel third channel at full until no noise can be heard from the machine at a minimum for one minute Put the fader of your desk back into position 0 and switch off the machine or your desk At Stand alone mode or operating via analog XLR remote Press the Mode button 14 until Co2 appears at the display Press the Enter button 16 once The fan starts to run automatically and thre...

Page 12: ...Enter button 18 Display 17 DMX LED yellow 20 Ready LED green 19 Cooling ready LED red C o 2 Fig 3 Display shown when the CO2 is expelled Fig 1 Display shown for adjusting the pump output Fig 2 Display shown for adjusting the DMX start address Fig 4 Display shown for switching off the device ...

Page 13: ...ically on minimum as soon as the pump or cooling channel is opened a Put the channel for the cooling to the maximum it depends on the adjusted DMX start address which channel this will be The channel for the cooling is always the two channels after the DMX start address For example Start address and pump 350 fan 351 cooling 352 The fan starts to run and after three seconds the CO2 valve opens The ...

Page 14: ... pump is fully opened the machine will not start the fogging process until the cooling chamber has reached the right cooling temperature c If necessary also the fan can now be regulated via the desk Important If you activate the pump first before you start the cooling process the machine will produce normal warm fog that goes up If you start the cooling process afterwards the machine will continue...

Page 15: ... three seconds the valve for the CO2 opens The machine now starts cooling the chamber but will not start to fog As soon as the cooling chamber is cold enough the red LED 19 illuminates and the fogging process starts The machine will now produce low fog at the adjusted output until the Enter button 16 is pressed again The pump can be adjusted during the fogging process by pressing the Up Down butto...

Page 16: ...er from time to time and clean or replace it when necessary Always replace the whole fluid canister rather than pouring new fluid into the old tank This reduces the chances of the machine clogging up If you install the Cryo Fog make 100 sure that a permanent fog free air supply for the unit is guaranteed Cooling air with too high fog concentration very often in Clubs and Discos can condense inside...

Page 17: ...n the PCB can cause fogging The fog machine switches off suddenly The temperature cutout has switched off due to overheating Remove external heat source for instance projector shining right onto the housing and or make sure sufficient fresh air supply After 15 to 30 minutes the unit should switch back to on again Loud droning sound during fogging The pump is running dry Avoid this absolutely Refil...

Page 18: ...O2 consumption at max output 4 4 lb min Fog output adjustable in 99 steps steps of 1 Fogging time continuous Control DMX 512 0 10 V analog Stand alone mode Warm up time approx 7 min Temperature control Microprocessor controlled Overheating protection Heater block Thermostat Pump Thermal switch Dimensions L x W x H 26 5 x 20 x 12 in Weight without tank 62 lbs Manufactured for Look Solutions Fog mac...

Page 19: ...s if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are not approved by us The right of guarantee service is also lost if fluids other than the authorized original Look fluids have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling trea...

Page 20: ...20 a Look Solutions product ...

Reviews: