background image

1

LOOK-C INSTRUCTIONS

WES Australasia 2014

2-Wire Video Intercom System

Technical Manual

Contents

„

„

Door„Entry„Security „ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

2 WIRE DOOR VIDEO INTERCOM SYSTEM  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

„

„

2„Wire„-„1„Door„-„1„Monitor„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

MINIMUM SYSTEM WITH PC6  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

MINIMUM SYSTEM WITH DPS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

„

„

2„Wire„-„1„Door„-„4„Monitors„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

EXPANDED SYSTEM WITH DAISY CHAIN .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

EXPANDED SYSTEM WITH STAR WIRING  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

„

„

2„Wire„-„4„Doors„-„1„Monitor„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

EXPANDED SYSTEM WITH STAR WIRING  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

„

„

2„Wire„-„4„Doors„-„16„Monitors„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

EXPANDED SYSTEM MAXIMUM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

„

„

2„Wire„-„CCTV„Controller„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

GENERAL SETUP DCU  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

EXPANDED SETUP DCU  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

„

„

2„Wire„-„Duplex„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

H292RH DUAL BUTTON SYSTEM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

H292RH MULTI-MONITORS   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

„

„

2„Wire„-„Cable„Information„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

RECOMMENDED WIRE SOLUTIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

„

„

Door„Strike„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

EXAMPLES OF DOOR STRIKE CONNECTION  .  .  .  .  .  .  .  .  .  .  .  . 7

„

„

2„Wire„-„Audio„Only„ .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

MINIMUM AUDIO SYSTEM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

EXPANDED AUDIO SYSTEM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

EXTENDED VIDEO SYSTEM WITH HANDSETS  .  .  .  .  .  .  .  .  .  .  . 8

Summary of Contents for H292RH

Page 1: ...XPANDED SYSTEM WITH STAR WIRING 3 2 Wire 4 Doors 1 Monitor 3 EXPANDED SYSTEM WITH STAR WIRING 3 2 Wire 4 Doors 16 Monitors 4 EXPANDED SYSTEM MAXIMUM 4 2 Wire CCTV Controller 5 GENERAL SETUP DCU 5 EXPA...

Page 2: ...EL971 All 2 Wire H2 products are compatible All operate on the same twisted pair wire No Polarity twisted pair easily to wire solution Use CAT5 or twin core drop cable or equivalent Cable distances c...

Page 3: ...m the Door Camera to the furthest of the monitors One common power supply to all type solution PC6 or DPS Monitor DIP Switches need setting Monitor Menu needs setting for Master Slave See Monitor Inst...

Page 4: ...e or equivalent Cable distance can be up to 100M from the Camera DPS Injector requires a 24V 5 Amp Power Pack DC 24V 5A Monitor DBC 4S BUS DS BUS IM BUS BUS Monitor Monitor Monitor Monitor DBC 4S BUS...

Page 5: ...ce eg Connect to your existing DVR Video Surveillance System etc Coax Power Door Camera 4a b Coax Power See Examples of Door Strike Connections Exit Button with time delay for door actuator Requires e...

Page 6: ...3 4 5 6 ON Monitor A Impedance DIP 6 off Monitor 1 Cam A 1 2 3 4 5 6 ON Monitor B Impedance DIP 6 off Monitor 17 Cam B 1 2 3 4 5 6 ON Power Door Strike PC6 BUS DS BUS IM AC Duplex A Duplex B Duplex Do...

Page 7: ...S2 SC BUS PL S1 S2 SC 1 2 3 JUMPER 1 2 3 JUMPER 1 2 3 JUMPER DOOR LATCH SAFE Strike can be set as Power Off To Release This is programmed into the door station via the monitor menu system See the Ins...

Page 8: ...trike Door Strike connections may vary to that shown A maximum of 16 Handsets and Monitors can be used in a system A combination of Daisy Chain and Star wiring DBC 4A is shown Set each Door Station Mo...

Page 9: ...TION 7 DOOR STRIKE 7 4 Wire Monitor Expanded 8 MULTI MONITOR READ ME 8 EXTEND TO AN EXTRA MONITOR H427 8 EXTEND MULTIPLE MONITORS 9 EXTEND TO A TV MONITOR 10 EXTEND AUDIO HANDSET 11 4 Wire Connection...

Page 10: ...urther information The diagrams on the following pages show connections for Look C 4 Wire Monitors and door cameras Where applicable both H424 and H427 connections are shown on the same diagrams For a...

Page 11: ...layer of the RVVPCable 7 JP_VD jumper To adjust the video impedance keep the jumper on the last Monitor and remove all on other Monitors When only one Monitor installed keep the jumper as in this cas...

Page 12: ...tup Installer Setup 2 Way Input and change the value to 1 AC 1R 2W 3Y 4B 1R 2W 3Y 4B 1 Electronic Lock Adapter Adapter 1 Door Station Monitor 2 Door Station AC 1R 2W 3Y 4B 1R 2W 3Y 4B 2 Electronic Loc...

Page 13: ...camera to the JS OS2 port 5 When using 2 door stations the 2 Way Input menu should be set to 1 on Monitor 1 On the Monitor Menu system go to User Setup Installer Setup 2 Way Input and change the value...

Page 14: ...connect multiple MDS in one system 3 SET switch for Doorstation or CCTV total number selection if connect 2 Doorstations and or Cameras set to left position set to middle position for 3 Doorstations...

Page 15: ...y Grannie Flats Teenagers Private Office Business A or B etc Fail Secure is Power On To Release The Door Station Camera has a Dry Relay Contact Connection Normally Open Connect using internal power is...

Page 16: ...Installer Restore Setup default Call tone Call tone Call tone Slaver Intercom Ring Volume Night Ring Volume Enter Code DO NOT MIX MONITORS Two styles of Monitors H424 4 Screen and H427 7 Screen models...

Page 17: ...nitor Do not use JS OS2 on other monitors Do not attach a door station or camera on any other monitor Extended Monitors in a single line bus 4 wire system An extra Monitor can be connected to Monitor...

Page 18: ...d on a BDU branch BDU will be required if using H4 24 units 3 Connect the video cable to the VIDEO terminal of the Televison Composite Video Input 4 Press the AV Button on the TV remote to switch the...

Page 19: ...inals optional will need enclosure 3 Connect the Doorstation to the JS OS1 port H427 4 Connect the Audio Phone to the JS AP port H424 5 Audio only handsets have no Video termination If Monitor end of...

Page 20: ...JS AP P 1R 2W 3Y 4B 2W 12V 4B P H4 24 Monitor H4 27 Monitor 2 The BDU unit is designed as a repeater and distribution amplifier for splitting a Bus into three branches Distribute the 4 Wire system in...

Page 21: ...he farest Monitor to the connected VT BDU should be less than 50 meters refer to Extend Multiple Monitors section for connection detail 9 Audio phones can be extended refer to Extend Audio Phone secti...

Page 22: ...3Y 4B JW OS HI 75R 150R SET 3Y Note SET 3Y set to 75R when the distance from door station to BDU is within 50 meters otherwise set to 150R MDS is connected with BDU in Star Configuration BDU BDU 4B 3...

Page 23: ...screen of the Monitor or by the external button RLC Terminal descriptions 45 mm 89 mm 70 mm RLC 1 2 3 4 ON NO NC COM 4B GND 12V BT 5 4 3 1 2 1 DIP switches for lamp control or unlock time settings see...

Page 24: ...4 ON Manual Mode Lamp manually control by button or Monitor DIP settings Monitor settings and operations Bit 1 Lamp Lock select set to OFF for lamp control set to ON for lock control Bit 2 Control mo...

Page 25: ...port 8 When connecting a lock with the safety type of Power on to Unlock connect to the NO and COM port DIP state Fail Secure is Power On To Release This is available standard with a Door Station Door...

Page 26: ...require 20AWG It is recommended to use shielded cable for noisy installations when runing cable with other wires like mains cord etc or steel structure buildings industrial etc It is recomended to us...

Page 27: ...n iron WES Cables Manufacturers Recommended Cables 2 Connect Security Cable SEC7505 Shielded for noisy environments Combine Red Brown wires for Power Combine White Green wires with shield for Common G...

Page 28: ...20 LOOK C INSTRUCTIONS WES Australasia VT Manual Update 2014...

Reviews: