VENTILA

VENTILA

VENTILA

VENTILA

VENTILATION INST

TION INST

TION INST

TION INST

TION INSTALLA

ALLA

ALLA

ALLA

ALLATION 

TION 

TION 

TION 

TION 

contin

contin

contin

contin

continued...

ued...

ued...

ued...

ued...

Clearance above grade, veranda, porch,
deck, or balcony

Clearnace to window or door that may be
opened

Clearance to permanently closed window

Vertical clearance to ventilated soffit lo-
cated above the terminal within a horizon-
tal distance of 2 feet (61 cm) from the cen-
ter line of the terminal

Clearnace to unventilated soffit

Clearance to outside corner

Clearnace to inside corner

Clearnace to each side of center line ex-
tended above meter/regulator assembly

Clearance to service regulator vent outlet

Clearance to nonmechanical air supply in-
let to building or the combustion air inlet to
any other appliance

Clearance to a mechanical air supply inlet

Clearnace above paved sidewalk or paved
driveway located on publis property

Clearance under veranda, porch, deck, or
balcony

A =

A =

A =

A =

A =

B =

B =

B =

B =

B =

C =

C =

C =

C =

C =
D =

D =

D =

D =

D =

E =

E =

E =

E =

E =
F =

F =

F =

F =

F =
G =

G =

G =

G =

G =
H =

H =

H =

H =

H =

I =

I =

I =

I =

I =
J =

J =

J =

J =

J =

K =

K =

K =

K =

K =

L =

L =

L =

L =

L =

M =

M =

M =

M =

M =

12 inches (30 cm)

6 inches (15 cm) for appliance < 10,000 BTU/hr
(3 kW), 12 inches (30 cm) for appliance > 10,000
BTU/hr (3 kW) and <100,000 BTU/hr (30 kW),
36 inches (91 cm) for appliances > 100,000 BTU/
hr (30 kW)

*

*

*

*

*

3 feet (91 cm) within a hieght 15 feet (4.5 m)

above the meter/regulator assembly

3 feet (91 cm)

6 inches (15 cm) for appliance < 10,000 BTU/hr
(3kW), 12 inches (30 cm) for appliance > 10,000
BTU/hr (3kW) and < 100,000 BTU/hr (30 kW),
36 inches (91 cm) for appliance > 100,000 BTU/
hr (30 kW)

6 feet (1.83 m)

7 feet (2.13 m) †

12 inches (30 cm) ‡

12 inches (30 cm)

6 inches (15 cm) for appliance < 10,000 BTU/hr
(3 kW), 9 inches (23 cm) for appliance > 10,000
BTU/hr (3 kW) and < 50,000 BTU/hr (15 kW), 12
inches (30 cm) for appliances > 50,000 BTU/hr
(15 kW)

*

*

*

*

*

*

*

6 inches (15 cm) for appliance < 10,000 BTU/hr
(3kW), 9 inches (23 cm) for appliance > 10,000
BTU/hr (3kW) and < 50,000 BTU/hr (15 kW), 12
inches (30 cm) for appliance > 50,000 BTU/hr
(15 kW)

3 feet (91 cm) above if within 10 feet (3 m)

horizontally

*

*

Canadian Installation 

Canadian Installation 

Canadian Installation 

Canadian Installation 

Canadian Installation 

11111

US Installation 

US Installation 

US Installation 

US Installation 

US Installation 

22222

11111

In accordance with the current 

CSA B149.1, Natural Gas and Propane Installation Code.

22222

In accordance with the current 

ANSI Z223.1/NFPA 54, National Fuel Gas Code.

†††††

A vent shall not terminate directly above a paved sidewalk or paved driveway that is located between two single family dwellings and serve both dwellings.

‡‡‡‡‡

Permitted only if verdana, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

*****

For clearnaces not specified in 

ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be indicated.

(a)  A minimum  clearances valve determined by testing in accordance with section 2.19.6, or ;
(b)  A reference to the following footnote:

“ Clearance in accordance with local installation codes and the requirements of the gas supplier.”

SBI Stove Builder International Inc.

7

Summary of Contents for DG05480

Page 1: ...tc witc witc witch h h h h do not do not do not do not do not use an use an use an use an use any phone in y y phone in y y phone in y y phone in y y phone in your b our b our b our b our building uil...

Page 2: ...avoid sticking of particles which would soil the wall You can feel safe with absolute security guaranteed by Its thermocouple security valve which cuts the supply of gas in the event of the heater ext...

Page 3: ...frequent c More frequent cleaning ma leaning ma leaning ma leaning ma leaning may be necessar y be necessar y be necessar y be necessar y be necessary due y due y due y due y due to e to e to e to e t...

Page 4: ...x it to the wall with adhesive tape Also take into consideration the other minimum distances shown on Diagram N 1 Dia Dia Dia Dia Diagram N 2 gram N 2 gram N 2 gram N 2 gram N 2 Model D Model D Model...

Page 5: ...lled holes Mark the hole for the 6 1 4 16cm dia ventilation tube This must be rectilinear and with a slight fall towards the exterior of approx 2 degrees to avoid the entering of rain water Take into...

Page 6: ...FE OPERA OPER AND SAFE OPERA OPER AND SAFE OPERATION TION TION TION TION VENTILA VENTILA VENTILA VENTILA VENTILATION INST TION INST TION INST TION INST TION INSTALLA ALLA ALLA ALLA ALLATION TION TION...

Page 7: ...000 BTU hr 3kW 12 inches 30 cm for appliance 10 000 BTU hr 3kW and 100 000 BTU hr 30 kW 36 inches 91 cm for appliance 100 000 BTU hr 30 kW 6 feet 1 83 m 7 feet 2 13 m 12 inches 30 cm 12 inches 30 cm 6...

Page 8: ...ST TION INST TION INST TION INST TION INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION contin contin contin contin continued ued ued ued ued Dia Dia Dia Dia Diagram N 8 gram N 8 gram N 8 gram N 8...

Page 9: ...t trap must be installed upstream of the heater to prevent moisture and contaminants from passing through the pipe to the heater controls and and contaminants from passing through the pipe to the heat...

Page 10: ...rwater Immediatelycallaqualifiedservicetechniciantoinspect the appliance and to replace any part of the control system and any gas control which has been under water A A A A A B B B B B C C C C C D D...

Page 11: ...Burner ve Burner ve Burner ve Burner Loosen the gas line from the burner on the right side of the unit On the left side of the unit unscrew the nut that holds the burner in place Then remove the burn...

Page 12: ...abel all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Permanently lubricated bearing system W W...

Page 13: ...DV20 DG05480 1 SPARE PARTS SBI Stove Builder International Inc 13...

Page 14: ...ol Bracket 1 20 1 2464 Piezo Ignitor Bracket 1 21 1 12455 Piezo Ignitor 1 22 1 11699 Piezo Ignitor Button 1 23 1 11698 Knob Frame 1 24 1 16365 Control Rod 1 25 1 11626 Control Knob 1 26 1 2477 Cabinet...

Page 15: ...DV12 DG05482 3 SPARE PARTS SBI Stove Builder International Inc 15...

Page 16: ...iezo Ignitor 1 19 2 11699 Piezo Ignitor Button 1 20 2 11698 Knob Frame 1 21 2 16365 Control Rod 1 22 2 11626 Control Knob 1 23 2 2461 Cabinet Back 1 24 2 2419 Top Deflector 1 25 2 2421 Left Side Defle...

Page 17: ...B B B BURNER ASSEMBL URNER ASSEMBL URNER ASSEMBL URNER ASSEMBL URNER ASSEMBLY REP Y REP Y REP Y REP Y REPAIR P AIR P AIR P AIR P AIR PAR AR AR AR ARTS TS TS TS TS SBI Stove Builder International Inc 1...

Page 18: ...6367 Burner Orifice DV12 Natural 1 22 3 16368 Burner Orifice DV12 Liquid Propane 1 23 3 16370 Burner Orifice DV20 Natural 1 24 3 16369 Burner Orifice DV20 Liquid Propane 1 25 3 16357 1 4 Compression S...

Page 19: ...0 1 4 4 2470 Connecting Rod 1 5 4 16371 Connecting Rod Nut 1 6 4 2475 Outgoing Flue Gases Tube DV12 Internal 1 7 4 2474 Air Incoming Tube DV12 External 1 8 4 344 Enameled Vent Cap DV12 1 SBI Stove Bui...

Page 20: ...the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part All parts and labour costs covered by this warranty are limited according to t...

Page 21: ...c 250 De Copenhague St Augustin de Desmaures Quebec Canada G1N 4R9 Tel 418 878 3040 Fax 418 878 3001 Web site www psg distribution com Online warranty registration We encourage you to register your wa...