background image

GAS SPECIFICA

GAS SPECIFICA

GAS SPECIFICA

GAS SPECIFICA

GAS SPECIFICATIONS

TIONS

TIONS

TIONS

TIONS

MODEL

MODEL

MODEL

MODEL

MODEL

FUEL

FUEL

FUEL

FUEL

FUEL

MAXIMUM INPUT

MAXIMUM INPUT

MAXIMUM INPUT

MAXIMUM INPUT

MAXIMUM INPUT

DV12

Natural

10,000 BTU/hr

Liquid Propane

10,000 BTU/hr

DV20

Natural

18,000 BTU/hr

Liquid Propane

18,000 BTU/hr

MANIFOLD PRESSURE

MANIFOLD PRESSURE

MANIFOLD PRESSURE

MANIFOLD PRESSURE

MANIFOLD PRESSURE

Natural Gas

D

DD

D

DV12

V12

V12

V12

V12

 - 5.8” w.c.

D

DD

D

DV20

V20

V20

V20

V20

 - 5.2” w.c.

Propane / LP Gas - 

D

DD

D

DV12

V12

V12

V12

V12

 - 10.8” w.c.

D

DD

D

DV20

V20

V20

V20

V20

 - 10.6” w.c.

GAS INLET

GAS INLET

GAS INLET

GAS INLET

GAS INLET

3/8” NPT

SUPPL

SUPPL

SUPPL

SUPPL

SUPPLYYYYY

MIN. PRESSURE

MIN. PRESSURE

MIN. PRESSURE

MIN. PRESSURE

MIN. PRESSURE

MAX. PRESSURE

MAX. PRESSURE

MAX. PRESSURE

MAX. PRESSURE

MAX. PRESSURE

Natural

7”  W.C.P.

10.5” W.C.P.

Propane / LP

11.0” W.C.P.

13.0” W.C.P.

USE ONL

USE ONL

USE ONL

USE ONL

USE ONLY 

Y THE 

THE 

THE 

THE 

THE TYPE GAS SPECIFIED ON 

TYPE GAS SPECIFIED ON 

TYPE GAS SPECIFIED ON 

TYPE GAS SPECIFIED ON 

TYPE GAS SPECIFIED ON THE RA

THE RA

THE RA

THE RA

THE RATING PLA

TING PLA

TING PLA

TING PLA

TING PLATE

TE

TE

TE

TE

INTR

INTR

INTR

INTR

INTRODUCTION

ODUCTION

ODUCTION

ODUCTION

ODUCTION

Your LONGVIE heater is especially designed to provide maximum comfort to you and your home.  Its large solid injected
aluminum front grill assures the optimum use of the generated heat in the ambient, maintains normal temperatures behind
the heater to avoid sticking of particles, which would soil the wall.  You can feel safe with absolute security guaranteed by:

Its thermocouple security valve, which cuts the supply of gas in the event of the heater extinguishing due to strong air
currents, momentary interruption of the supply of gas.

Its gas pressure regulator assures an optimum operational; function, avoiding peak pressures in the gas supply
affecting normal combustion.

Its gas tight combustion chamber, totally enameled, avoids gases which are caused by combustion, to contaminate
the air and ensures a useful , long lasting working life.

Long lasting working life...Guaranteed by the quality of its components and high technology applied in the process of
fabrication, and especially by the traditional vocation of LONGVIE to produce durable products for your maximum comfort
and satisfaction.

LOCAL CODES

LOCAL CODES

LOCAL CODES

LOCAL CODES

LOCAL CODES

Install and use the heater with care.  The installation must conform with local codes or in the absence
of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.  Natural
Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home OEM installation must conform with the 

Manufac-

tured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for 

Manufactured Home Installation, ANSI Z225.1, or Standard for Gas

Equipped recreational Vehicles and Mobile Housing, CSA Z240.4.

*Available from:

National Fire Protection  Association, Inc.

Batterymarch Park

Quincy, MA  02269

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

SBI Stove Builder International Inc.

2

Summary of Contents for DG05480

Page 1: ...tc witc witc witch h h h h do not do not do not do not do not use an use an use an use an use any phone in y y phone in y y phone in y y phone in y y phone in your b our b our b our b our building uil...

Page 2: ...avoid sticking of particles which would soil the wall You can feel safe with absolute security guaranteed by Its thermocouple security valve which cuts the supply of gas in the event of the heater ext...

Page 3: ...frequent c More frequent cleaning ma leaning ma leaning ma leaning ma leaning may be necessar y be necessar y be necessar y be necessar y be necessary due y due y due y due y due to e to e to e to e t...

Page 4: ...x it to the wall with adhesive tape Also take into consideration the other minimum distances shown on Diagram N 1 Dia Dia Dia Dia Diagram N 2 gram N 2 gram N 2 gram N 2 gram N 2 Model D Model D Model...

Page 5: ...lled holes Mark the hole for the 6 1 4 16cm dia ventilation tube This must be rectilinear and with a slight fall towards the exterior of approx 2 degrees to avoid the entering of rain water Take into...

Page 6: ...FE OPERA OPER AND SAFE OPERA OPER AND SAFE OPERATION TION TION TION TION VENTILA VENTILA VENTILA VENTILA VENTILATION INST TION INST TION INST TION INST TION INSTALLA ALLA ALLA ALLA ALLATION TION TION...

Page 7: ...000 BTU hr 3kW 12 inches 30 cm for appliance 10 000 BTU hr 3kW and 100 000 BTU hr 30 kW 36 inches 91 cm for appliance 100 000 BTU hr 30 kW 6 feet 1 83 m 7 feet 2 13 m 12 inches 30 cm 12 inches 30 cm 6...

Page 8: ...ST TION INST TION INST TION INST TION INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION contin contin contin contin continued ued ued ued ued Dia Dia Dia Dia Diagram N 8 gram N 8 gram N 8 gram N 8...

Page 9: ...t trap must be installed upstream of the heater to prevent moisture and contaminants from passing through the pipe to the heater controls and and contaminants from passing through the pipe to the heat...

Page 10: ...rwater Immediatelycallaqualifiedservicetechniciantoinspect the appliance and to replace any part of the control system and any gas control which has been under water A A A A A B B B B B C C C C C D D...

Page 11: ...Burner ve Burner ve Burner ve Burner Loosen the gas line from the burner on the right side of the unit On the left side of the unit unscrew the nut that holds the burner in place Then remove the burn...

Page 12: ...abel all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Permanently lubricated bearing system W W...

Page 13: ...DV20 DG05480 1 SPARE PARTS SBI Stove Builder International Inc 13...

Page 14: ...ol Bracket 1 20 1 2464 Piezo Ignitor Bracket 1 21 1 12455 Piezo Ignitor 1 22 1 11699 Piezo Ignitor Button 1 23 1 11698 Knob Frame 1 24 1 16365 Control Rod 1 25 1 11626 Control Knob 1 26 1 2477 Cabinet...

Page 15: ...DV12 DG05482 3 SPARE PARTS SBI Stove Builder International Inc 15...

Page 16: ...iezo Ignitor 1 19 2 11699 Piezo Ignitor Button 1 20 2 11698 Knob Frame 1 21 2 16365 Control Rod 1 22 2 11626 Control Knob 1 23 2 2461 Cabinet Back 1 24 2 2419 Top Deflector 1 25 2 2421 Left Side Defle...

Page 17: ...B B B BURNER ASSEMBL URNER ASSEMBL URNER ASSEMBL URNER ASSEMBL URNER ASSEMBLY REP Y REP Y REP Y REP Y REPAIR P AIR P AIR P AIR P AIR PAR AR AR AR ARTS TS TS TS TS SBI Stove Builder International Inc 1...

Page 18: ...6367 Burner Orifice DV12 Natural 1 22 3 16368 Burner Orifice DV12 Liquid Propane 1 23 3 16370 Burner Orifice DV20 Natural 1 24 3 16369 Burner Orifice DV20 Liquid Propane 1 25 3 16357 1 4 Compression S...