Connect each station to the switch by twisted-pair cable. Plug one 
RJ-45 connector into a RJ-45 port of the switch, and plug the other
RJ-45 connector into the station’s network adapter. Power on the
switch and then system is ready.

For cable selection, refer to the following table.

In making a switch interconnection, you could use any port to
connect another switch with straight or crossover cable. As all the
ports support auto MDI / MDI-X function, using a straight cable to
make a switch-to-switch connection is allowed.

For cable selection, refer to the following table

Κ

Network Speed 

Cable Type

Max. Length

10Mbps

Cat. 3, 4, 5 UTP/STP

100 meters

100Mbps

Cat. 5 UTP/STP

100 meters

Rack-Mount

Rack-Mount Installation (Rack-mount kit is optional for 13-inch 
model)

3

The switch may standalone, or may be mounted in a standard
19-inch equipment rack. Rack mounting produces an orderly 
installation when you have a number of related network devices.
The switch is supplied with two optional rack mounting brackets and 
screws. These are used for rack mounting the unit.

Summary of Contents for LCS-883R-SW24N

Page 1: ...ion issue This switch also supports auto MDI MDI X function Each port could be used to connect to another switch or hub with no crossover RJ 45 cable Store and forward switching mode promises the low...

Page 2: ...Steady Green Power is on Power Off Power is off Steady Green Connected as 100Mbps 100M Off Connected as 10Mbps Steady Green The port is connected Blinking Green The port is transmitting receiving dat...

Page 3: ...o MDI MDI X function using a straight cable to make a switch to switch connection is allowed For cable selection refer to the following table Network Speed Cable Type Max Length 10Mbps Cat 3 4 5 UTP S...

Page 4: ...trol Interface 24 10 100Mbps RJ 45 Fast Ethernet Ports Uplink Auto MDI MDI X Auto crossover Network Speed 10 100Mbps Full Half duplex mode auto detection MAC Addr Table 14K MAC entries Memory 192Kbyte...

Page 5: ...to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Ma...

Page 6: ...formity With Standards Results EN 55022 1994 A1 1995 A2 1997 Class A Pass EN 61000 3 2 1995 A1 1998 A2 1998 Class A Pass EN 61000 3 3 1995 Pass EN 55024 1998 Pass 61000 4 2 1995 Pass 61000 4 3 1995 Pa...

Page 7: ...nformity With Standards Results EN 55022 1994 A1 1995 A2 1997 Class A Pass EN 61000 3 2 1995 A1 1998 A2 1998 Class A Pass EN 61000 3 3 1995 Pass EN 55024 1998 Pass 61000 4 2 1995 Pass 61000 4 3 1995 P...

Reviews: