Use this clip spring to tight the fogging tube adapter to the machine. 

 

8.2 If still spay fire, it means the power of the machine is too strong, you need 

reduce the 

power,

 please check below, 

Rotate adjust knob to 

right direction

 until 

to the end, for adjust back to the standard site of 

the carburetor.

 

 

After adjusted back to the standard site, if it still spray flame, please do adjustment as 

below, 

Summary of Contents for TS-34

Page 1: ...r pump handle while right hand press down igniter button to pump machine slowly Until after heard 1 or 2 explosion sounds pull up oil valve then pump a little bit quickly will start up machine if stil...

Page 2: ...1 3 Maybe after heard 1 or 2 explosive sounds like Peng Peng then switch on oil valve as below Press on igniter pump machine will start Note Firstly pump machine slowly after heard explosive sounds li...

Page 3: ...1 4 If could not start machine please switch off the oil valve 1 5 pump machine like below 1 6 Then switch on oil valve 1 7 Then pump machine like below will start machine...

Page 4: ...le points to Convex This is the Standard Site for starting machine or for machine working stably Before machine leaves our factory we have already fixed well the standard site 2 2 Some time if you cou...

Page 5: ...eard the Pu Pu Pu sounds please do the adjustment as below Use left hand to hold the adjust knob make sure it will not move Then use the screwdriver insert into the screw rotate to right direction for...

Page 6: ...start machine please do the adjustment as below Use left hand to hold the adjust knob make sure it will not move Then use the screwdriver insert into the screw rotate to Left direction for 1 8 circle...

Page 7: ...out Keep put finger into the hole use left hand to pump air pump then use right hand finger to feel whether if there have gasoline spray out if do not have rotate Adjust Knob of carburetor to increase...

Page 8: ...n press on the igniter button there do not have clearly ignition sounds like Ta Ta or the ignition sounds is very low not loud enough please do following Hit one of the Pins a little bit Please only a...

Page 9: ...5 mm it will increase the ignition electric voltage help more easy start up machine 4 Check diaphragm Disassemble diaphragm clean diaphragm spacer plates diaphragm must clean free of bends cracks Che...

Page 10: ...install it back appropriately Please note the right procedure for install back 2 1 2 3 4 Please note this diaphragm must be in the middle position appropriately if it is misplaced could not start mac...

Page 11: ...5 6 7 8 9 10 11 12 Note This screw should be tight if it is loose could not start machine Please insert into the 3 units screw simultaneously then use screwdriver to tighten them...

Page 12: ...t way shows Baffle Valve Right way Wrong way the diaphragm will move 2 After install well diaphragm please make sure the fixed plate is rightly covered the diaphragm as following picture A shows Fixed...

Page 13: ...ed But the Illustration B is not in gear need fix back appropriately if the diaphragm is broken or change shape please find new spare parts inside spare parts kits as below to change it Disassemble th...

Page 14: ...A Only photo A show the gaskets is properly placed all the other photos is wrong B...

Page 15: ...art up 6 How to discharge the residual chemicals in the chemicals tank Use screw driver loose the Bolt as Picture A B shows let the residual chemicals go out A B Note After finishing discharging the c...

Page 16: ...ease flow rate Note Normally just keep it turn on no need to adjust it in every time for use In 99 00 chance this problem as below will not happen Some time the adjustable flow rate valve s handle is...

Page 17: ...Take out the handle as below...

Page 18: ...The inside is loose please ask us to give you the new handle of the adjustable flow...

Page 19: ...valve Then you use small spanner rotate the small screw into the hole lock the position of the handle 7 2 Check the lid of chemicals tank to see if there have rubber gasket inside There should have ru...

Page 20: ...side check following parts 7 4 1 Check the airway pipe whether broken if broken please replace new one 7 4 2 Check the one way valve Please get back to the above mentioned Step 5 Check whether one way...

Page 21: ...ide chemicals tank please check following parts 7 5 1 Disassemble the bolt at the bottom of chemical tank check the filter is jammed If the filter is jammed clean it install it back appropriately 7 5...

Page 22: ...k the connected nail to find if there has deposited carbon inside clean like below Check deposited carbon Clean deposited carbon After cleaning please install back appropriately 7 6 Check whether the...

Page 23: ...then install back appropriately 8 When working suddenly spray flame or fire 8 1 Some time customer do not install the fogging tube adapter to machine for working it is wrong Note Please must install F...

Page 24: ...means the power of the machine is too strong you need reduce the power please check below Rotate adjust knob to right direction until to the end for adjust back to the standard site of the carburetor...

Page 25: ...k whether it will spray flame or not 8 3 If it still spray flame please rotate to right direction for another 1 8 circle again now it will definitely not spray flame 8 4 After done the above mentioned...

Reviews: