11
6.2 PREARRANGEMENTS
Make sure the cable sections and the plug are suitable for the power absorbed by the apparatus.
IT IS FORBIDDEN TO USE CABLE EXTENSIONS, ADAPTORS AND MULTIPLE - OUTLET SOCKETS
Be careful not to install the refrigerator near to heat sources, such as ovens, radiators, direct sunlight, etc.
Leave at least a 75 mm space (3 inches) between back of cabinet and wall (if this is the case), to
prevent formation of condensation.
Keep the engine compartment clear of any obstacle that may impede or limit air-flow through the
condensing unit located in the refrigerator front lower part.
Make sure the area where the refrigerator is installed is adequately ventilated to guarantee proper
cooling of the condenser and compressor unit.
To ensure effective performance and operation of the refrigerator, make sure the temperature of the
area where it is installed will not exceed 30° C (86 F).
Failure to comply with the foregoing conditions may be detrimental to the refrigerator’s overall
performance, and cause premature wear and tear and abnormally high power usage.
Also see the information under paragraph 1.5
6.3 CONNECTIONS
To avoid any kind of problem during start up, follow the procedures described below.
6.3.1 ELECTRICAL CONNECTIONS
The Client is in charge of making the necessary electrical connections. Connections to the power line
must be made in compliance with the regulations in force in the country where the refrigerator is being
installed.
Make sure the power supply voltage corresponds exactly to the indications stated on the label plate
affixed to the refrigerator (see Label Plate A).
Make sure the socket is in conformity with the relevant regulations in force.
Carefully check for any bare wires.
GROUNDING OF THE REFRIGERATOR IS A MANDATORY SAFETY REQUIRMENT
(see Label Plate C).
In case multiple devices need to be aligned, each one must be powered separately.
In order to protect the refrigerator’s electrical system from power overload or short-circuit, an overload switch
with adequate breaking power must be installed upstream of the refrigerator socket (see Label Plate D).
7. F U N C T I O N I N G
7.1 OPERATORS
Staff in charge of operating and installing the refrigerator must have (or have acquired through appropriate
schooling and training course) the qualifications listed below and must also be acquainted with this manual
and all safety related information contained therein
:
General and technical culture at sufficient level to understand the contents of this manual.
Knowledge of the most important standards related to hygiene in the workplace, accident -
prevention and technology
.
Summary of Contents for VITRA
Page 19: ...18 7 5 1 ALLARM LIST ...