Fig. 15
Hold eyeball inside return fitting
adaptor with eyeball insert toward
inside. Thread on the return fitting
cover to secure eyeball position so it
directs flow away from skimmer
opening. Do not overtighten.
Fig. 16
Connect hose from inlet of pump to
the port located on the bottom of the
skimmer body. A hose clamp should
be used to secure hose.
Fig. 17
Connect hose from filter system
return to the pool return fitting. A
hose clamp should be used to secure
hose.
Fig. 12
Hold the return fitting body so the
hose fitting end is pointing straight
up. Tighten the adaptor from inside
the pool until gasket contact is
made.
Fig. 13
Hold adaptor inside of pool and turn
the return fitting body clockwise to its
straight down position. If the
assembly does not feel snug, rotate
the return fitting body back to its
upright position. Rotate the adaptor
inside pool an additional 1/4 turn.
Rotate the body to the down position
again. Repeat this procedure as
required.
EYEBALL INSERT
EYEBALL
Fig. 14
Push eyeball insert into eyeball.
Fig. 9
From inside the pool, place a board
against the liner and hold it firmly
against the return fitting cutout in the
metal wall. Use a razor knife to cut
out the liner return hole.
Fig. 10
Slip one return fitting gasket over the
threaded end of the return fitting
adaptor and, from the inside of pool,
insert through the cut in liner and
wall.
Fig. 11
Place second gasket over threads on
return fitting adaptor and lightly
engage threads into return fitting
body.
4
RETURN FITTING
ADAPTOR
POOL
WALL
LINER
GASKET