background image

5

 Possible malfunctions

You can correct most malfunctions by yourself. 
For all other problems contact the LOMAC-licensed service station.

SUVERAIN

®

www.lomac.de

PROBLEM

•Thedevicedoesnotswitch

off properly.

•Thedeviceswitcheson

 

intermittently. 

•Themotorisrunningin

 

severalcyclesandthewater

inthetoiletbowlonly

 

dischargesslowly.

•Themotorisrunning

 

correctly but does not  

switchoffcorrectly,orruns

foraverylongtime.

•Themotorisnotstartingup

•Themotorisrunningwith

 

arattlingsoundorgrumbles

anddoesnotwork.

•Waterrefluxintheshower

 

is muddy.

PROBABLE CAUSES

•Thedevicehasbeenpumping

fortoolong(thermo-switch

for safety).

•Failureofthecontrolsystem.

•Theconnectedsanitary

 

installationsareleaky

 

(tap,cistern).

•Theflaptrapisnotclosing

tightly.

•Theventilationopening

 

inthelidisblocked.

•Thedischargepipeistoo

highortoolongorthere

aretoomanybends(lossof

pressure)

•Thepumpfloorisblocked.

•Thedeviceisnotconnected.

•Socketisdamaged

•Problemwiththemotoror

the control system

•Themotorisblockedby

 

aforeignobject.

•Problemwiththemotor

 

or the control system 

•Theshowerhasbeeninstalled

toolowdowninrelationto

the device.

•Theflaptrapsfortheside

inletsareblocked.

REMEDIES

•Pulltheplugoutofthe

 

socket.Waitforanhourand

re-connect.

•Otherwisecontacta

 

licensed customer service 

representative.

•Checktheconnectedwaste

disposal.

•Cleanorchangetheflap

trap.

•Cleantheventilation

 

connection.

•Checktheinstallation.

•Otherwisecontact

 

alicensedbreakdownservice.

•Connectthedevice.

•Otherwisecontact

 

a licensed customer  

service representative.

•Removetheforeignbody

 

(seesection6).

•Otherwisecontact

 

a licensed customer  

service representative.

•Checktheinstallation.

•Cleantheflaptrapsfromthe

outside,otherwisecontact

a licensed customer service 

representative. 

6

 Disassembly

PLEASE NOTE: Repairs to the motor and electrical 

parts may only be undertaken by licensed  

professionals. Before interfering with the device 

disconnect the electrical connection.

 

a.  Dismantling the macerator  

from the WC bowl

 •TurnoffwaterfeedtoWCcisternand

 

removethelargestquantitypossibleofwater
fromthesiphonoftheWC-bowl.

 •Disconnectthepressurepipe.
 •Suverain3000-A:Cutoffthewatersupply.
 •DisconnectthedevicefromtheWC.

b. Foreign bodies

RemovetheforeignbodythroughtheWCinletand
usingascrewdriveroranironwire.

Be careful not to pierce the rubber gasket.

PLEASE NOTE: The blades are very sharp – never 

put your hand into the device.

7

 Warranty

TheSuverain3000-Aproductshavea2yearwarranty.
Thewarrantywillbeimmediatelynullifiedifthe

 

conditions of installation and use  
are not observed.

Summary of Contents for SUVERAIN 3000-A

Page 1: ...elle befestigen d Elektrischer Anschluß ACHTUNG Die elektrischen Anschlüsse müssen nach der Montage des Gerätes hergestellt werden Die für ein Badezimmer geltenden Bestimmungen für den elektrischen Anschluß einhalten Der elektrische Anschluß muß von einem Fachmann hergestellt werden Den Apparat an eine Steckdose 10 16 A 2 Pole Erdung anschließen Die Steckdose darf nur zur Versorgung des Apparats d...

Page 2: ...ker aus der Steckdose ziehen Eine Stunde warten und wieder anschließen Andernfalls sich an einen zugelassenen Kundendienst wenden Die angeschlossenen Entsorger kontrollieren Die Rückschlagklappe reinigen oder austauschen Das Lüftungsloch reinigen Den Einbau überprüfen Andernfalls sich an einen zugelassenen Pannendienst wenden Das Gerät anschließen Andernfalls sich an einen zugelassenen Kundendiens...

Page 3: ...amp Then connect the discharge pipe to the neck and fix with a pipe clamp d Electrical connection PLEASE NOTE The electrical connections must be made after assembling the device For the electrical connection be aware of the regulations applicable for a bathroom The electrical connection must be made by a professional Connect the appliance to a 2 pole 10 16 A socket earthing The socket may only ser...

Page 4: ...MEDIES Pull the plug out of the socket Wait for an hour and re connect Otherwise contact a licensed customer service representative Check the connected waste disposal Clean or change the flap trap Clean the ventilation connection Check the installation Otherwise contact a licensed breakdown service Connect the device Otherwise contact a licensed customer service representative Remove the foreign b...

Reviews: